-31.0 dBm
MIN (P + 4.0 dB OR -31.0 dBm)
O
P (P + 1.5 dB < P < -31.0 dBm)
A
O
A
P
= MAX (P OR -45.0 dBm)
S
O
S
2
(P = INPUT POWER FOR BER < 10 )
INPUT OPTICAL POWER
INPUT OPTICAL POWER
>
(
>
(
1.5 dB STEP INCREASE)
4.0 dB STEP DECREASE)
-45.0 dBm
ANS MAX
–
AS MAX
–
SIGNAL DETECT (ON)
–
SIGNAL DETECT (OFF)
–
TIME
AS MAX — MAXIMUM ACQUISITION TIME (SIGNAL).
–
AS MAX IS THE MAXIMUM SIGNAL DETECT ASSERTION TIME FOR THE STATION.
–
–
AS MAX SHALL NOT EXCEED 100.0 µs. THE DEFAULT VALUE OF AS MAX IS 100.0 µs.
–
–
ANS MAX — MAXIMUM ACQUISITION TIME (NO SIGNAL).
–
ANS MAX IS THE MAXIMUM SIGNAL DETECT DEASSERTION TIME FOR THE STATION.
–
–
ANS MAX SHALL NOT EXCEED 350 µs. THE DEFAULT VALUE OF AS MAX IS 350 µs.
–
–
Figure 12. Signal Detect Thresholds and Timing.
HFBR-5103, -5104, and -5105 Series
Absolute Maximum Ratings
Parameter
Storage Temperature
Lead Soldering Temperature
Lead Soldering Time
Supply Voltage
Symbol
TS
Min.
Typ.
Max.
100
260
10
Unit
°C
Reference
-40
TSOLD
tSOLD
VCC
°C
sec.
V
-0.5
-0.5
7.0
Data Input Voltage
Differential Input Voltage
Output Current
V
I
VCC
1.4
V
VD
IO
V
Note 1
50
mA
138