Applications
Typical applications for the
HCTL-1100 include printers,
medical instruments, material
handling machines, and industrial
automation.
HCTL-1100 vs.
HCTL-1000
The HCTL-1100 is designed to
replace the HCTL-1000. Some
differences exist, and some
enhancements have been added.
System Block Diagram
Comparison of HCTL-1100 and HCTL-1000
Description
Max. Supply Current
Max. Power Dissipation
HCTL-1100
30 mA
HCTL-1000
180 mA
165 mW
950 mW
Max. Tri-State Output
Leakage Current
150 nA
10 µA
Operating Frequency
100 kHz-2 MHz
1 MHz-2 MHz
Operating Temperature
Range
-20°C to +85°C
0°C to 70°C
Storage Temperature Range
Synchronize 2 or More ICs
-55°C to +125°C -40°C to +125°C
Yes
–
Preset Actual Position
Registers
Yes
Yes
–
–
Read Flag Register
Limit and Stop Pins
Must be pulled
up to VDD if
not used.
Can be left
floating if not
used.
Hard Reset
Required
Yes
Recommended
–
PLCC Package Available
2-140