Package Characteristics
Parameter
Input-Output Momentary
Withstand Voltage**
Option 020
Resistance
(Input-Output)
Capacitance
(Input-Output)
Input-Input Insulation
Leakage Current
Input-Input Insulation
Leakage Current
Capacitance
(Input-Input)
R
I-O
C
I-O
I
I-I
R
I-I
C
I-I
2730
2731
0730
0731
0.005
10
11
0.03
0.25
Device
Symbol HCPL- Min. Typ.* Max. Units
V
ISO
2730
2731
2500
5000
10
12
0.6
pF
µA
pF
V rms
Test Conditions
RH
50%,
t = 1 min.,
T
A
= 25°C
V
I-O
= 500 VDC
RH
45%
f = 1 MHz
RH
45%
V
I-I
= 500 VDC
Fig. Note
4, 9
4, 10
4
11
5
5
5
*All Typical values at T
A
= 25°C unless otherwise noted.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if appli-
cable), your equipment level safety specification or HP Application Note 1074 entitled “Optocoupler Input-Output Endurance
Voltage.”
Notes:
1. Pin 5 should be the most negative
voltage at the detector side.
2. Each channel.
3. DC CURRENT TRANSFER RATIO
(CTR) is defined as the ratio of output
collector current, I
O
, to the forward
LED input current, I
F
, times 100%.
4. Device considered a two-terminal
device: pins 1, 2, 3, and 4 shorted
together, and pins 5, 6, 7, and 8
shorted together.
5. Measured between pins 1 and 2
shorted together, and pins 3 and 4
shorted together.
6. Common mode transient immunity in a
Logic High level is the maximum
tolerable (positive) dV
CM
/dt of the
common mode pulse, V
CM
, to assure
that the output will remain in a Logic
High state (i.e., V
O
> 2.0 V). Common
mode transient immunity in a Logic
Low level is the maximum tolerable
(negative) dV
CM
/dt of the common
mode pulse, V
CM
, to assure that the
output will remain in a Logic Low state
(i.e., V
O
< 0.8 V).
7. In applications where dV/dt may
exceed 50,000 V/µs (such as static
discharge) a series resistor, R
CC
,
should be included to protect the
detector IC from destructively high
surge currents. The recommended
value is R
CC
= 110
Ω.
8. Use of a 0.1
µF
bypass capacitor
connected between pins 5 and 8
adjacent to the device is
recommended.
9. In accordance with UL 1577, each
optocoupler is proof tested by
applying an insulation test voltage
> 3000 V rms for 1 second (leakage
detection current limit, I
I-O
< 5
µA).
10. In accordance with UL 1577, each
optocoupler is proof tested by
applying an insulation test voltage
> 6000 V rms for 1 second (leakage
detection current limit, I
I-O
< 5
µA).
11. Measured between the LED anode and
cathode shorted together and pins 5
through 8 shorted together.
12. Derate linearly above 65°C free-air
temperature at a rate of 2.3 mW/°C for
the SO-8 package.
1-117