6
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Symbol
L(101)
HCPL-J314
7.4
Units
mm
Conditions
Measured from input terminals
to output terminals, shortest
distance through air.
Measured from input terminals
to output terminals, shortest
distance path along body.
Through insulation distance
conductor to conductor, usually
the straight line distance
thickness between the emitter
and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE
0110, 1/89, Table 1)
L(102)
8.0
mm
0.5
mm
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
CTI
>175
IIIa
V
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Average Input Current
Peak Transient Input Current (<1
µs
pulse
width, 300pps)
Reverse Input Voltage
“High” Peak Output Current
“Low” Peak Output Current
Supply Voltage
Output Voltage
Output Power Dissipation
Input Power Dissipation
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
T
S
T
A
I
F(AVG)
I
F(TRAN)
V
R
I
OH(PEAK)
I
OL(PEAK)
V
CC
-V
EE
V
O(PEAK)
P
O
P
I
-0.5
-0.5
Min.
-55
-40
Max.
125
100
25
1.0
3
0.6
0.6
35
V
CC
260
105
Units
°C
°C
mA
A
V
A
A
V
V
mW
mW
3
4
2
2
1
Note
260°C for 10 sec., 1.6 mm below seating plane
See
Package Outline Drawings
section