4
Solder Reflow Temperature Profile
300
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
2.5°C ± 0.5°C/SEC.
160°C
150°C
140°C
3°C + 1°C/–0.5°C
30
SEC.
30
SEC.
SOLDERING
TIME
200°C
Regulatory Information
The HCPL-J314 has been
approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
UL
Approval under UL 1577,
component recognition program
up to V
ISO
= 3750 V
rms
. File
E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
TEMPERATURE (°C)
200
100
PREHEATING TIME
150°C, 90 + 30 SEC.
50 SEC.
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
0
0
50
100
150
200
250
TIME (SECONDS)
Recommended Pb-Free IR Profile
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
20-40 SEC.
t
p
T
p
T
L
260 +0/-5 °C
217 °C
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
TEMPERATURE
T
smax
T
smin
RAMP-DOWN
6 °C/SEC. MAX.
t
s
PREHEAT
60 to 180 SEC.
25
t 25 °C to PEAK
TIME
t
L
60 to 150 SEC.
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C