Regulatory Information
The HCPL-7510 has been approved by the following organizations:
UL
IEC/EN/DIN EN 60747-5-2
Approved under:
Approved under UL 1577, component recognition
program up to VISO = 3750 VRMS. File E55361.
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
CSA
Approved under CSA Component Acceptance
Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics[1]
Description
Symbol
Characteristic Unit
Installation classification per DIN EN 0110-1ꢀ1997-04, Table 1
for rated mains voltage - 150 Vrms
for rated mains voltage - 300 Vrms
I – IV
I – III
I – II
for rated mains voltage - 600 Vrms
Climatic Classification
55ꢀ100ꢀ21
2
Pollution Degree (DIN EN 0110-1ꢀ1997-04)
Maximum Working Insulation Voltage
VIORM
VPR
891
Vpeak
Vpeak
Input to Output Test Voltage, Method b[2]
VIORM x 1.875 = VPR, 100% production test with tm = 1 sec, partial discharge <5 pC
1670
Input to Output Test Voltage, Method a[2]
VIORM x 1.5 = VPR, type and sample test, tm = 60 sec, partial discharge <5 pC
VPR
1336
6000
Vpeak
Vpeak
Highest Allowable Overvoltage (transient overvoltage tini = 10 sec)
VIOTM
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
TS
175
400
600
°C
mA
mW
[3]
Input Current
I
S, INPUT
[3]
Output Power
P
S, OUTPUT
Insulation Resistance at TS, VIO = 500 V
RS
>109
Ω
Notes:
800
1. Insulation characteristics are guaranteed only within the safety maximum ratings which must be
ensured by protective circuits within the application. Surface Mount Classifications is Class A in
accordance with CECC00802.
P
(mW)
S
700
600
500
400
300
I
(mA)
S
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,
under Product Safety Regulations section,
(IECꢀENꢀDIN EN 60747-5-2) for a detailed description of Method a and Method b partial
discharge test profiles.
3. Refer to the following figure for dependence of P and I on ambient temperature.
S
S
200
100
0
0
25 50 75 100 125 150 175 200
– CASE TEMPERATURE – C
T
S
5