欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-7510-060 参数 Datasheet PDF下载

HCPL-7510-060图片预览
型号: HCPL-7510-060
PDF下载: 下载PDF文件 查看货源
内容描述: 隔离线性传感IC [Isolated Linear Sensing IC]
分类和应用: 模拟IC信号电路
文件页数/大小: 16 页 / 117 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HCPL-7510-060的Datasheet PDF文件第1页浏览型号HCPL-7510-060的Datasheet PDF文件第2页浏览型号HCPL-7510-060的Datasheet PDF文件第3页浏览型号HCPL-7510-060的Datasheet PDF文件第4页浏览型号HCPL-7510-060的Datasheet PDF文件第6页浏览型号HCPL-7510-060的Datasheet PDF文件第7页浏览型号HCPL-7510-060的Datasheet PDF文件第8页浏览型号HCPL-7510-060的Datasheet PDF文件第9页  
Regulatory Information  
The HCPL-7510 has been approved by the following organizations:  
UL  
IEC/EN/DIN EN 60747-5-2  
Approved under:  
Approved under UL 1577, component recognition  
program up to VISO = 3750 VRMS. File E55361.  
IEC 60747-5-2:1997 + A1:2002  
EN 60747-5-2:2001 + A1:2002  
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.  
CSA  
Approved under CSA Component Acceptance  
Notice #5, File CA 88324.  
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics[1]  
Description  
Symbol  
Characteristic Unit  
Installation classification per DIN EN 0110-1ꢀ1997-04, Table 1  
for rated mains voltage - 150 Vrms  
for rated mains voltage - 300 Vrms  
I – IV  
I – III  
I – II  
for rated mains voltage - 600 Vrms  
Climatic Classification  
55ꢀ100ꢀ21  
2
Pollution Degree (DIN EN 0110-1ꢀ1997-04)  
Maximum Working Insulation Voltage  
VIORM  
VPR  
891  
Vpeak  
Vpeak  
Input to Output Test Voltage, Method b[2]  
VIORM x 1.875 = VPR, 100% production test with tm = 1 sec, partial discharge <5 pC  
1670  
Input to Output Test Voltage, Method a[2]  
VIORM x 1.5 = VPR, type and sample test, tm = 60 sec, partial discharge <5 pC  
VPR  
1336  
6000  
Vpeak  
Vpeak  
Highest Allowable Overvoltage (transient overvoltage tini = 10 sec)  
VIOTM  
Safety-limiting values – maximum values allowed in the event of a failure.  
Case Temperature  
TS  
175  
400  
600  
°C  
mA  
mW  
[3]  
Input Current  
I
S, INPUT  
[3]  
Output Power  
P
S, OUTPUT  
Insulation Resistance at TS, VIO = 500 V  
RS  
>109  
Notes:  
800  
1. Insulation characteristics are guaranteed only within the safety maximum ratings which must be  
ensured by protective circuits within the application. Surface Mount Classifications is Class A in  
accordance with CECC00802.  
P
(mW)  
S
700  
600  
500  
400  
300  
I
(mA)  
S
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,  
under Product Safety Regulations section,  
(IECꢀENꢀDIN EN 60747-5-2) for a detailed description of Method a and Method b partial  
discharge test profiles.  
3. Refer to the following figure for dependence of P and I on ambient temperature.  
S
S
200  
100  
0
0
25 50 75 100 125 150 175 200  
– CASE TEMPERATURE – C  
T
S
5
 复制成功!