6
Switching Specifications
For 0°C ≤ T ≤ 70°C, 4.5 V ≤ VCC ≤ 20 V, all typicals at TA = 25°C and VCC = 5 V unless otherwise noted.
A
See note 12.
Parameter
Symbol Min. Typ.
Max. Units Test Conditions
Fig. Note
Propagation Delay Time
to Logic High Output Level
tPLH
0.3
1.6
µs
CO = 1000 pF,
CL = 15 pF,
IO = 20 mA
5, 6,
7
6
Propagation Delay Time
to Logic Low Output Level
tPHL
0.2
1.0
µs
CO = 1000 pF,
CL = 15 pF,
IO = 20 mA
5, 6,
7
7
Propagation Delay Time
Skew
Output Rise Time
(10-90%)
tPLH - tPHL
tr
0.1
16
µs
IO = 20 mA
ns
IO = 20 mA,
CO = 1000 pF,
CL = 15 pF
6, 8
6, 8
8
9
Output Fall Time
(90-10%)
tf
23
ns
IO = 20 mA,
CO = 1000 pF,
CL = 15 pF
Common Mode Transient
Immunity at Logic High
Output Level
|CMH| 1,000 10,000
V/µs V = 2 V,
9, 10
10
I
T = 25°C
A
VCM = 50 V (peak),
VCC = 5 V
IO (min.) = 12 mA
Common Mode Transient
Immunity at Logic Low
Output Level
|CML|
1,000 10,000
V/µs V = 0.8 V,
9, 10
11
I
T = 25°C
A
VCM = 50 V (peak),
VCC = 5 V
IO (max.) = 3 mA
Package Characteristics
For 0°C ≤ TA ≤ 70°C, unless otherwise specified. All typicals at TA = 25°C.
Parameter
Symbol Min. Typ. Max. Units
Test Conditions
Fig. Notes
Input-Output Momentary
Withstand Voltage*
Resistance, Input-Output
Capacitance, Input-Output
VISO
2500
V rms RH ≤ 50%, t = 1 min,
T = 25°C
5, 13
5
A
RI-O
CI-O
1012
1
ohms VI-O = 500 V dc
pF
f = 1 MHz,
VI-O = 0 V dc
5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”