6
Switching Specifications  
For 0°C T 70°C, 4.5 V VCC 20 V, all typicals at TA = 25°C and VCC = 5 V unless otherwise noted.  
A
See note 12.  
Parameter  
Symbol Min. Typ.  
Max. Units Test Conditions  
Fig. Note  
Propagation Delay Time  
to Logic High Output Level  
tPLH  
0.3  
1.6  
µs  
CO = 1000 pF,  
CL = 15 pF,  
IO = 20 mA  
5, 6,  
7
6
Propagation Delay Time  
to Logic Low Output Level  
tPHL  
0.2  
1.0  
µs  
CO = 1000 pF,  
CL = 15 pF,  
IO = 20 mA  
5, 6,  
7
7
Propagation Delay Time  
Skew  
Output Rise Time  
(10-90%)  
tPLH - tPHL  
tr  
0.1  
16  
µs  
IO = 20 mA  
ns  
IO = 20 mA,  
CO = 1000 pF,  
CL = 15 pF  
6, 8  
6, 8  
8
9
Output Fall Time  
(90-10%)  
tf  
23  
ns  
IO = 20 mA,  
CO = 1000 pF,  
CL = 15 pF  
Common Mode Transient  
Immunity at Logic High  
Output Level  
|CMH| 1,000 10,000  
V/µs V = 2 V,  
9, 10  
10  
I
T = 25°C  
A
VCM = 50 V (peak),  
VCC = 5 V  
IO (min.) = 12 mA  
Common Mode Transient  
Immunity at Logic Low  
Output Level  
|CML|  
1,000 10,000  
V/µs V = 0.8 V,  
9, 10  
11  
I
T = 25°C  
A
VCM = 50 V (peak),  
VCC = 5 V  
IO (max.) = 3 mA  
Package Characteristics  
For 0°C TA 70°C, unless otherwise specified. All typicals at TA = 25°C.  
Parameter  
Symbol Min. Typ. Max. Units  
Test Conditions  
Fig. Notes  
Input-Output Momentary  
Withstand Voltage*  
Resistance, Input-Output  
Capacitance, Input-Output  
VISO  
2500  
V rms RH 50%, t = 1 min,  
T = 25°C  
5, 13  
5
A
RI-O  
CI-O  
1012  
1
ohms VI-O = 500 V dc  
pF  
f = 1 MHz,  
VI-O = 0 V dc  
5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output  
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),  
your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”