欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-3150 参数 Datasheet PDF下载

HCPL-3150图片预览
型号: HCPL-3150
PDF下载: 下载PDF文件 查看货源
内容描述: 0.5安培输出电流IGBT栅极驱动光电耦合器 [0.5 Amp Output Current IGBT Gate Drive Optocoupler]
分类和应用: 栅极光电输出元件双极性晶体管栅极驱动
文件页数/大小: 16 页 / 254 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HCPL-3150的Datasheet PDF文件第2页浏览型号HCPL-3150的Datasheet PDF文件第3页浏览型号HCPL-3150的Datasheet PDF文件第4页浏览型号HCPL-3150的Datasheet PDF文件第5页浏览型号HCPL-3150的Datasheet PDF文件第7页浏览型号HCPL-3150的Datasheet PDF文件第8页浏览型号HCPL-3150的Datasheet PDF文件第9页浏览型号HCPL-3150的Datasheet PDF文件第10页  
Switching Specifications (AC)
Over recommended operating conditions (T
A
= -40 to 100°C, I
F(ON)
= 7 to 16 mA, V
F(OFF)
= -3.0 to 0.8 V,
V
CC
= 15 to 30 V, V
EE
= Ground) unless otherwise specified.
Parameter
Propagation Delay
Time to High
Output Level
Symbol
t
PLH
Min.
0.10
Typ.*
0.30
Max.
0.50
Units
µs
Test Conditions
Rg = 47
Ω,
Cg = 3 nF,
f = 10 kHz,
Duty Cycle = 50%
Fig.
10, 11,
12, 13
14, 23
Note
14
Propagation Delay
t
PHL
0.10
Time to Low
Output Level
Pulse Width
PWD
Distortion
Propagation Delay
PDD
-0.35
Difference Between (t
PHL
- t
PLH
)
Any Two Parts
Rise Time
t
r
Fall Time
t
f
UVLO Turn On
t
UVLO ON
Delay
UVLO Turn Off
t
UVLO OFF
Delay
Output High Level
|CM
H
|
15
Common Mode
Transient
Immunity
Output Low Level
|CM
L
|
15
Common Mode
Transient
Immunity
0.27
0.50
µs
0.3
0.35
µs
µs
34,35
15
10
0.1
0.1
0.8
0.6
30
µs
µs
µs
µs
kV/µs
23
V
O
> 5 V,
I
F
= 10 mA
V
O
< 5 V,
I
F
= 10 mA
T
A
= 25°C,
I
F
= 10 to 16 mA,
V
CM
= 1500 V,
V
CC
= 30 V
T
A
= 25°C,
V
CM
= 1500 V,
V
F
= 0 V,
V
CC
= 30 V
22
24
11, 12
30
kV/µs
11, 13
Package Characteristics
Parameter
Symbol
Input-Output
V
ISO
Momentary
Withstand Voltage**
Resistance
R
I-O
(Input - Output)
Capacitance
C
I-O
(Input - Output)
LED-to-Case
θ
LC
Thermal Resistance
LED-to-Detector
θ
LD
Thermal Resistance
Detector-to-Case
θ
DC
Thermal Resistance
Min.
2500
Typ.*
Max.
Units
Vrms
Test Conditions
RH < 50%,
t = 1 min.,
T
A
= 25°C
V
I-O
= 500 V
DC
f = 1 MHz
Thermocouple
located at center
underside of
package
28
Fig.
Note
8, 9
10
12
0.6
391
439
119
pF
°C/W
°C/W
°C/W
9
*All typical values at T
A
= 25°C and V
CC
- V
EE
= 30 V, unless otherwise noted.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to your equipment level safety specification or HP Application Note
1074 entitled “Optocoupler Input-Output Endurance Voltage.”
1-202