Switching Specifications (AC)
For 0°C
≤
T
A[1]
≤
85°C, 4.5 V
≤
V
CC
≤
20 V, 1.6 mA
≤
I
F(ON)
≤
5 mA, 0.0 mA
≤
I
F(OFF)
≤
0.1 mA.
All Typicals at T
A
= 25°C, V
CC
= 5 V, I
F(ON)
= 3 mA unless otherwise specified.
Parameter
Propagation Delay Time to
Logic Low Output Level
Propagation Delay Time to
Logic High Output Level
Output Enable Time to
Logic High
Output Enable Time to
Logic Low
Output Disable Time from
Logic High
Output Disable Time from
Logic Low
Output Rise Time (10-90%)
Output Fall Time (90-10%)
Sym.
t
PHL
t
PLH
t
PZH
t
PZL
t
PHZ
t
PLZ
t
r
t
f
Min. Typ. Max. Units
Test Conditions
210
ns
Without Peaking Capacitor
160 300
With Peaking Capacitor
170
ns
Without Peaking Capacitor
115 300
With Peaking Capacitor
25
ns
28
105
60
55
15
ns
ns
ns
ns
ns
Fig. Note
5, 6 4, 5
5, 6
7, 9
7, 8
7, 9
7, 8
5, 10
5, 10
4, 5
Parameter
Logic High
Common Mode
Transient
Immunity
Logic Low
Common Mode
Transient
Immunity
Sym.
|CM
H
|
Device
HCPL-2200
HCPL-2219
Min.
1,000
2,500
1,000
2,500
Units
V/µs
V/µs
V/µs
V/µs
Test Conditions
I
F
= 1.6 mA
|V
CM
| = 50 V
V
CC
= 5 V
T
A
= 25°C
|V
CM
| = 400 V
|V
CM
| = 50 V
|V
CM
| = 400 V
V
F
= 0 V
V
CC
= 5 V
T
A
= 25°C
Fig.
11
Note
6
|CM
L
|
HCPL-2200
HCPL-2219
11
6
Package Characteristics
Parameter
Input-Output Momentary
Withstand Voltage*
Input-Output Resistance
Input-Output Capacitance
Sym.
V
ISO
R
I-O
C
I-O
Min.
2500
Typ.
Max. Units
V rms
Ω
pF
Test Conditions
RH
≤
50%, t = 1 min.,
T
A
= 25°C
V
I-O
= 500 VDC
f = 1 MHz, V
I-O
= 0 VDC
Fig. Note
3, 8
3
3
10
12
0.6
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable), your equipment level
safety specification or HP Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage,” publication number 5963-2203E.
1-127