 浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第33页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第34页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第35页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第36页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第38页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第39页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第40页浏览型号UT80CRH196KD-WCX的Datasheet PDF文件第41页  
of Timer3 can be found in locations 0Fh (high byte), and 0Eh  
(low byte) of HWindow 1.  
PROCESSING FLOW FOR THE ST R0, [R0]+  
INSTRUCTION  
1.15 Input/Output Pullup/Pulldown Currents  
UT80CRH196KD  
Address = [R0]; 1000h  
R0 ---> Address  
Industry Standard  
Address = [R0]; 1000h  
R0 = R0+1; 1001h  
R0 ---> Address  
Leakage currents may not meet the industry standard specs due  
to differently sized weak pullups/pulldowns, during Quasi-  
Bidirectional and reset/powerdown modes. Refer to specs for  
ILI1 and ILI2  
.
R0 = R0+1; 1001h  
* The contents in address  
1000h are 1000h  
* The contents in address  
1000h are 1001h  
1.16 Power-down exit  
Pin 37 will not be used to exit power-down mode. Since a digital  
clock is supplied, no connection between this Vpp pin and the  
power-down circuitry exists.  
1.23 AC Timing Differences  
There are some AC timing differences between the  
1.17 Test Mode Entry  
UT80CRH196KD and the industry standard 80C196KD. Most  
changes resulted in loosened timing specifications. However,  
the tRHDZ and tRXDX timing specifications were tightened by  
Test mode entry will be via four pins: WR, RD, ALE andHLDA  
instead of PWM0.  
1.18 Power-on Reset  
5ns. If you have been designing to the industry standard timing  
specifications, it is important to recognize these two shortened  
timing specifications.  
The UT80CRH196KD will not guarantee the 16-state "pulse  
stretching" function of a Reset_n pulse applied at power-up. The  
user must hold Reset_n low until the power and clocks stabilize  
plus 16-state times, or provide a high to low transition after the  
power and clocks have stabilized.  
NOTE: Please visit the UTMC website at www.utmc.com to  
obtain the latest data sheet updates, application notes, software  
examples, advisories and erratas for the UT80CRH196KD.  
1.19 Pullup/Pulldown states  
1.24 T2UP-DN Input Signal  
The INST pin will be driven to a weak low during Reset. The  
ALE signal will be driven to a weak high during Bus Hold.  
Port 2.6 has an alternate function of T2UP-DN enabled by  
IOC2.1. The industry standard device appears to allow writes  
into Port 2.6 to directly affect the pin state when in the T2UP-  
DN mode. (This would allow software control of the T2 direc-  
tion, but requires ensuring a one (QBD pullup) is written to  
Port 2.6 if the pin is driven externally). The UT80CRH196KD  
device is designed to disable the Port 2.6 output when T2UP-  
DN is enabled. This protects the P2.6/T2UP-DN pin from con-  
tention with an externally driven signal, independent of the  
value written into Port 2.  
1.20 Modifying the INT_PEND registers  
Two operand rd-modify-wr instructions should be used to  
modify the INT_PEND registers. Three operand rd-modify-wr  
instructions may lose an incoming interrupt.  
1.21 Serial Port Synchronous Mode  
The last clock rising edge to output float time (TXHQZ) is made  
consistent with the output data hold (TXHQX) time of 2 TOSC  
+/-50nsec. This is longer than the industry standard of 1 TOSC  
max.  
1.25 NEG 8000h Instruction Operation  
1.22 Industry Standard Register Indirect with Auto Incre-  
ment  
The UT80CRH196KD and the industry standard 80C196KD  
set the N-Flag differently when executing the NEG 8000h  
instruction. NEG represents the MCS-96 opcode to negate a  
defined operand (8000h). When the UT80CRH196KD exe-  
cutes the NEG 8000h instruction, the result becomes 8000h  
with both the N-Flag and the V-Flag set. The industry stan-  
dard 80C196KD, however, executes the NEG 8000h instruc-  
tion with a result of 8000h and only the V-Flag set.  
The industry standard increments the auto-incremented regis-  
ter after determining the external address instead of at the end  
of the instruction completion. The UT80CRH196KD performs  
the auto-increment function at the end of the instruction pro-  
cessing. Please reference the example below that shows the  
processing difference between the UT80CRH196KD and the  
industry standard:  
ST R0, [R0]+  
assume R0 holds the value 1000h before the instruction is exe-  
cuted.  
1.26 Reserved Opcode EEH  
The industry standard 80C196KD using the MCS-96 ISA  
declares the opcode EEH as a reserved opcode and does not  
37  