Data Sheet
ADuM1400/ADuM1401/ADuM1402
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 13.
Parameter
Rating
Storage Temperature (TST)
Ambient Operating Temperature (TA)1
Ambient Operating Temperature (TA)2
−65°C to +150°C
−40°C to +105°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to VDDI + 0.5 V
−0.5 V to VDDO + 0.5 V
3
Supply Voltages (VDD1, VDD2
)
Input Voltage (VIA, VIB, VIC, VID, VE1, VE2)3, 4
3, 4
Output Voltage (VOA, VOB, VOC, VOD
)
ESD CAUTION
Average Output Current per Pin5
Side 1 (IO1)
−18 mA to +18 mA
Side 2 (IO2)
Common-Mode Transients6
−22 mA to +22 mA
−100 kV/μs to +100 kV/μs
1 Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W
automotive grade versions.
2 Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade
versions.
3 All voltages are relative to their respective ground.
4 VDDI and VDDO refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PC Board Layout section.
5 See Figure 4 for maximum rated current values for various temperatures.
6 This refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the Absolute Maximum Ratings
may cause latch-up or permanent damage.
Table 14. Maximum Continuous Working Voltage1
Parameter
Max
Unit
Constraint
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Basic Insulation
Reinforced Insulation
DC Voltage
565
V peak
50-year minimum lifetime
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Basic Insulation
Reinforced Insulation
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1 Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Table 15. Truth Table (Positive Logic)
VIx Input1 VEx Input1, 2 VDDI State1 VDDO State1 VOx Output1
Notes
H
L
X
X
X
X
H or NC
H or NC
L
H or NC
L
X
Powered
Powered
Powered
Unpowered Powered
Unpowered Powered
Powered
Powered
Powered
H
L
Z
H
Z
Outputs return to the input state within 1 μs of VDDI power restoration.
Powered
Unpowered Indeterminate Outputs return to the input state within 1 μs of VDDO power restoration
if the VEx state is H or NC. Outputs return to a high impedance state
within 8 ns of VDDO power restoration if the VEx state is L.
1 VIx and VOx refer to the input and output signals of a given channel (A, B, C, or D). VEx refers to the output enable signal on the same side as the VOx outputs. VDDI and
VDDO refer to the supply voltages on the input and output sides of the given channel, respectively.
2 In noisy environments, connecting VEx to an external logic high or low is recommended.
Rev. H | Page 21 of 32