 浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第16页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第17页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第18页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第19页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第21页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第22页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第23页浏览型号ADUM1400CRWZ-RL的Datasheet PDF文件第24页  
ADuM1400/ADuM1401/ADuM1402  
Data Sheet  
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS  
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by  
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.  
Table 11.  
Description  
Conditions  
Symbol Characteristic Unit  
Installation Classification per DIN VDE 0110  
For Rated Mains Voltage ≤ 150 V rms  
For Rated Mains Voltage ≤ 300 V rms  
For Rated Mains Voltage ≤ 400 V rms  
Climatic Classification  
Pollution Degree per DIN VDE 0110, Table 1  
Maximum Working Insulation Voltage  
Input-to-Output Test Voltage, Method B1  
I to IV  
I to III  
I to II  
40/105/21  
2
VIORM  
VPR  
560  
1050  
V peak  
V peak  
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,  
partial discharge < 5 pC  
Input-to-Output Test Voltage, Method A  
After Environmental Tests Subgroup 1  
After Input and/or Safety Test Subgroup 2 VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC  
and Subgroup 3  
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC  
VPR  
896  
672  
V peak  
V peak  
Highest Allowable Overvoltage  
Safety-Limiting Values  
Transient overvoltage, tTR = 10 seconds  
Maximum value allowed in the event of a failure  
(see Figure 4)  
VTR  
4000  
V peak  
Case Temperature  
Side 1 Current  
Side 2 Current  
TS  
IS1  
IS2  
RS  
150  
265  
335  
>109  
°C  
mA  
mA  
Ω
Insulation Resistance at TS  
VIO = 500 V  
350  
300  
250  
RECOMMENDED OPERATING CONDITIONS  
Table 12.  
Parameter  
Rating  
Operating Temperature (TA)1  
Operating Temperature (TA)2  
−40°C to +105°C  
−40°C to +125°C  
2.7 V to 5.5 V  
3.0 V to 5.5 V  
1.0 ms  
SIDE #2  
200  
150  
100  
50  
1, 3  
Supply Voltages (VDD1, VDD2  
Supply Voltages (VDD1, VDD2  
)
)
2, 3  
SIDE #1  
Input Signal Rise and Fall Times  
1 Does not apply to ADuM1400W, ADuM1401W, and ADuM1402W automotive  
grade versions.  
2 Applies to ADuM1400W, ADuM1401W, and ADuM1402W automotive grade  
versions.  
0
3 All voltages are relative to their respective ground. See the DC Correctness  
and Magnetic Field Immunity section for information on immunity to  
external magnetic fields.  
0
50  
100  
CASE TEMPERATURE (°C)  
150  
200  
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values  
with Case Temperature per DIN V VDE V 0884-10  
Rev. H | Page 20 of 32  
 
 
 