 浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第17页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第18页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第19页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第20页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第22页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第23页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第24页浏览型号ADuM1201ARZ-RL7的Datasheet PDF文件第25页  
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 13.
Parameter
Storage Temperature (T
ST
)
Ambient Operating Temperature (T
Ambient Operating Temperature (T
Supply Voltages (V
DD1
, V
DD2
Input Voltages (V
IA
, V
IB
Output Voltages (V
OA
Average Output Current per Pin (I
Common-Mode Transients (CM
L
, CM
1
ADuM1200/ADuM1201
Rating
−55°C to +150°C
−40°C to +105°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to V
DDI
+ 0.5 V
−0.5 V to V
DDO
+ 0.5 V
−11 mA to +11 mA
−100 kV/μs to +100 kV/μs
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Does not apply to ADuM1200W and ADuM1200W automotive grade
products.
2
Applies to ADuM1200W and ADuM1201W automotive grade products.
3
All voltages are relative to their respective ground.
4
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively.
5
See Figure 3 for maximum rated current values for various temperatures.
6
Refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the absolute maximum ratings
can cause latch-up or permanent damage.
Table 14. Maximum Continuous Working Voltage
Parameter
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Functional Insulation
Basic Insulation
DC Voltage
Functional Insulation
Basic Insulation
1
Max
565
1131
560
1131
560
Unit
V peak
V peak
V peak
V peak
V peak
Constraint
50-year minimum lifetime
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Rev. I | Page 21 of 28