ADM811/ADM812
ABSOLUTE MAXIMUM RATINGS
Typical values are at T
A
= 25°C, unless otherwise noted.
Table 2.
Parameter
Terminal Voltage (With Respect to Ground)
V
CC
All Other Inputs
Input Current
V
CC
MR
Output Current
RESET
Power Dissipation (T
A
= 70°C)
RA-4 (SOT-143)
Derate by 4 mW/°C Above 70°C
θ
JA
Thermal Impedance
Operating Temperature Range
Storage Temperature Range
Lead Temperature (Soldering, 10 sec)
Vapor Phase (60 sec)
Infrared (15 sec)
ESD Rating
Rating
−0.3 V to +6 V
−0.3 V to V
CC
+ 0.3 V
20 mA
20 mA
20 mA
200 mW
330°C/W
−40°C to +85°C
−65°C to +160°C
300°C
215°C
220°C
3 kV
Data Sheet
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Rev. G | Page 4 of 12