 浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第2页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第3页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第4页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第5页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第7页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第8页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第9页浏览型号ADM3486EARZ-REEL7的Datasheet PDF文件第10页  
ADM3483E/ADM3486E/ADM3488E/ADM3490E/ADM3491E  
VCC = 3.3 V, TA = 25°C.  
Table 5. ADM3490E/ADM3491E  
Parameter  
Symbol  
Min  
12  
1
Typ  
15  
Max  
Unit  
Mbps  
ns  
Test Conditions/Comments  
MAXIMUM DATA RATE  
DIFFERENTIAL OUTPUT DELAY  
DIFFERENTIAL OUTPUT TRANSITION TIME  
PROPAGATION DELAY  
tDD  
tTD  
22  
35  
25  
RL = 60 Ω (see Figure 10)  
RL = 60 Ω (see Figure 10)  
3
11  
ns  
From Low to High Level  
From High to Low Level  
|tPLH − tPHL| PROPAGATION DELAY SKEW1  
ENABLE/DISABLE TIMING (ADM3491E ONLY)  
Enable Time to Low Level  
tPLH  
tPHL  
tPDS  
7
7
23  
23  
35  
35  
±±  
ns  
ns  
ns  
RL = 27 Ω (see Figure 11)  
RL = 27 Ω (see Figure 11)  
RL = 27 Ω (see Figure 11)  
−1.4  
tPZL  
tPZH  
tPLZ  
tPHZ  
tPSL  
tPSH  
42  
42  
35  
35  
650  
650  
90  
90  
±0  
±0  
900  
900  
ns  
ns  
ns  
ns  
ns  
ns  
RL = 110 Ω (see Figure 13)  
RL = 110 Ω (see Figure 12)  
RL = 110 Ω (see Figure 13)  
RL = 110 Ω (see Figure 12)  
RL = 110 Ω (see Figure 13)  
RL = 110 Ω (see Figure 12)  
Enable Time to High Level  
Disable Time from Low Level  
Disable Time from High Level  
Enable Time from Shutdown to Low Level  
Enable Time from Shutdown to High Level  
1 Measured on |tPLH (Y) − tPHL (Y)| and |tPLH (Z) − tPHL (Z)|.  
RECEIVER TIMING SPECIFICATIONS  
VCC = 3.3 V, TA = 25°C.  
Table 6. ADM3483E/ADM3486E/ADM3488E/ADM3490E/ADM3491E  
Parameter  
Symbol Min Typ Max Unit  
Test Conditions/Comments  
PROPAGATION DELAY  
From Low to High Level  
tRPLH  
ADM34±6E/ADM3490E/ADM3491E  
ADM34±3E/ADM34±±E  
25  
25  
62  
75  
90  
120  
ns  
ns  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
From High to Low Level  
tRPHL  
ADM34±6E/ADM3490E/ADM3491E  
ADM34±3E/ADM34±±E  
25  
25  
62  
75  
90  
120  
ns  
ns  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
|tRPLH − tRPHL| PROPAGATION DELAY SKEW  
ADM34±6E/ADM3490E/ADM3491E  
ADM34±3E/ADM34±±E  
tRPDS  
+6  
±10  
ns  
ns  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
VID = 0 V to 3.0 V, CL = 15 pF (see Figure 14)  
+12 ±20  
ENABLE/DISABLE TIMING (ADM34±3E/ADM34±6E/  
ADM3491E ONLY)  
Enable Time to Low Level  
Enable Time to High Level  
tRPZL  
tRPZH  
tRPLZ  
tRPHZ  
tRPSL  
tRPSH  
tSHDN  
25  
25  
25  
25  
50  
50  
45  
45  
ns  
ns  
ns  
ns  
CL = 15 pF (see Figure 15)  
CL = 15 pF (see Figure 15)  
CL = 15 pF (see Figure 15)  
CL = 15 pF (see Figure 15)  
CL = 15 pF (see Figure 15)  
CL = 15 pF (see Figure 15)  
Disable Time from Low Level  
Disable Time from High Level  
Enable Time from Shutdown to Low Level  
Enable Time from Shutdown to High Level  
Time to Shutdown1  
720 1400 ns  
720 1400 ns  
190 300  
±0  
ns  
1 The transceivers are put into shutdown mode by bringing the high and the DE low. If the inputs are in this state for less than ±0 ns, the parts are guaranteed not to  
RE  
enter shutdown. If the parts are in this state for 300 ns or more, the parts are guaranteed to enter shutdown.  
Rev. A | Page 6 of 20  
 
 
 