VDE 0884 INSULATION CHARACTERISTICS
This isolator is suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data must be ensured by
means of protective circuits.
An asterisk (*) on packages denotes VDE 0884 approval for 560 V peak working voltage.
Table 5.
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110 for rated mains voltage
≤150 V rms
≤300 V rms
≤400 V rms
Climatic classification
Pollution degree (DIN VDE 0110, Table 1)
Maximum working insulation voltage
Input to output test voltage, Method b1
VIORM × 1.875 = VPR, 100% production tested, tm = 1 sec, partial discharge < 5 pC
Input to output test voltage, Method a
(After environmental tests, Subgroup 1)
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC
(After input and/or safety test, Subgroup 2/3)
VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC
Highest allowable overvoltage
I to IV
I to III
I to II
40/85/21
2
VIORM
VPR
560
1050
VPEAK
VPEAK
896
VPEAK
VPEAK
VPEAK
VPR
VTR
672
(Transient overvoltage, tTR = 10 sec)
4000
Safety-limiting values (maximum value allowed in the event of a failure. See
thermal derating curve)
Case temperature
Input current
Output current
TS
150
265
335
>109
°C
IS, INPUT
IS, OUTPUT
Rs
mA
mA
Ω
Insulation resistance at Ts, VIO = 500 V