500 kbps, ESD Protected, Half-/Full-Duplex,  
iCoupler, Isolated RS-485 Transceiver  
ADM2484E  
FEATURES  
FUNCTIONAL BLOCK DIAGRAM  
V
V
DD2  
DD1  
Isolated, RS-485/RS-422 transceiver, configurable as half- or  
full-duplex  
15 kV ESD protection on RS-485 input/output pins  
500 kbps data rate  
ADM2484E  
DE  
Complies with ANSI TIA/EIA RS-485-A-1998 and  
ISO 8482: 1987(E)  
Y
Z
TxD  
Suitable for 5 V or 3.3 V operation (VDD1  
)
High common-mode transient immunity: >25 kV/μs  
True fail-safe receiver inputs  
256 nodes on the bus  
A
B
RxD  
RE  
Thermal shutdown protection  
Safety and regulatory approvals pending  
UL recognition  
5000 V rms isolation voltage for 1 minute per UL1577  
VDE certificate of conformity  
GND  
GND  
2
1
Figure 1.  
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12  
Reinforced insulation, VIORM = 848 V peak  
Operating temperature range: −40°C to +85°C  
Wide body, 16-lead SOIC package  
APPLICATIONS  
Isolated RS-485/RS-422 interfaces  
Industrial field networks  
INTERBUS  
Multipoint data transmission systems  
GENERAL DESCRIPTION  
technology to combine a 3-channel isolator, a three-state  
differential line driver, and a differential input receiver into a  
single pacꢀage.  
The ADM2484E is an isolated data transceiver with ±±1 ꢀk  
ESD protection suitable for high speed, half- or full-duplex  
communication on multipoint transmission lines. For half-  
duplex operation, the transmitter outputs and receiver inputs  
share the same transmission line. Transmitter Output Pin Y  
linꢀs externally to Receiver Input Pin A, and Transmitter  
Output Pin Z linꢀs externally to Receiver Input Pin B.  
The differential transmitter outputs and receiver inputs feature  
electrostatic discharge circuitry that provides protection up to  
±±1 ꢀk using the human body model (HBM). The logic side of  
the device can be powered with either a 1 k or a 3.3 k supply,  
whereas the bus side requires an isolated 3.3 k supply.  
Designed for balanced transmission lines, the ADM2484E  
complies with ANSI TIA/EIA RS-481-A-±998 and ISO 8482:  
±987(E). The device employs Analog Devices, Inc., iCoupler®  
The device has current-limiting and thermal shutdown features  
to protect against output short circuits and situations where bus  
contention causes excessive power dissipation.  
Rev. 0  
Information furnished by Analog Devices is believed to be accurate and reliable. However, no  
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other  
rights of third parties that may result from its use. Specifications subject to change without notice. No  
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.  
Trademarks and registeredtrademarks arethe property of their respective owners.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.461.3113  
www.analog.com  
©2008 Analog Devices, Inc. All rights reserved.