ADM1032
1. Although it is possible to read a data byte from a data register
without first writing to the Address Pointer Register, if the
Address Pointer Register is already at the correct value, it is
not possible to write data to a register without writing to the
Address Pointer Register, because the first data byte of a
write is always written to the Address Pointer Register.
1
SCLK
9
2. Don’t forget that some of the ADM1032 registers have differ-
ent addresses for read and write operations. The write address
of a register must be written to the Address Pointer if data is
to be written to that register, but it is not possible to read
data from that address. The read address of a register must
be written to the Address Pointer before data can be read
from that register.
1
9
SDATA
START BY
MASTER
A6
A5
A4
A3
A2
A1
A0
R/W
ACK. BY
ADM1032
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1032
FRAME 1
SERIAL BUS ADDRESS BYTE
1
SCLK (CONTINUED)
FRAME 2
ADDRESS POINTER REGISTER BYTE
9
SDATA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1032
STOP BY
MASTER
FRAME 3
DATA BYTE
Figure 3a. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
SCLK
9
1
9
SDATA
START BY
MASTER
A6
A5
A4
A3
A2
A1
A0
R/W
ACK. BY
ADM1032
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1032
STOP BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
Figure 3b. Writing to the Address Pointer Register Only
1
SCLK
9
1
9
SDATA
START BY
MASTER
A6
A5
A4
A3
A2
A1
A0
R/W
ACK. BY
ADM1032
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1032
STOP BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
DATA BYTE FROM ADM1032
Figure 3c. Reading Data from a Previously Selected Register
ALERT
OUTPUT
The
ALERT
output goes low whenever an out-of-limit mea-
surement is detected, or if the remote temperature sensor is
open-circuit. It is an open drain and requires a pull-up to V
DD
.
Several
ALERT
outputs can be wire-ORed together, so that the
common line will go low if one or more of the
ALERT
outputs
goes low.
The
ALERT
output can be used as an interrupt signal to a
processor, or it may be used as an
SMBALERT.
Slave devices
on the SMBus can normally not signal to the master that they
want to talk, but the
SMBALERT
function allows them to do so.
One or more
ALERT
outputs can be connected to a common
SMBALERT
line connected to the master. When the
SMBALERT
line is pulled low by one of the devices, the fol-
lowing procedure occurs as illustrated in Figure 4.
MASTER
RECEIVES
SMBALERT
START
ALERT RESPONSE ADDRESS
MASTER SENDS
ARA AND READ
COMMAND
RD
ACK
DEVICE ADDRESS
NO
ACK
STOP
DEVICE SENDS
ITS ADDRESS
Figure 4. Use of
SMBALERT
REV. 0
–9–