ADG508F/ADG509F
Parameter
Charge Injection
Off Isolation
C
S
(Off )
C
D
(Off )
POWER REQUIREMENTS
I
DD
I
SS
1
+25°C
15
93
3
22
12
0.05
0.1
B Version
−40°C to +85°C
Unit
pC typ
dB typ
pF typ
pF typ
pF typ
Test Conditions/Comments
V
S
= 0 V, R
S
= 0 Ω, C
L
= 1 nF; see Figure 30
R
L
= 1 kΩ, C
L
= 15 pF, f = 100 kHz; V
S
= 7 V rms;
see Figure 31
0.2
1
mA max
μA max
V
IN
= 0 V or 5 V
Guaranteed by design, not subject to production test.
TRUTH TABLES
Table 2.
Truth Table
A2
X
0
0
0
0
1
1
1
1
1
A1
X
0
0
1
1
0
0
1
1
A0
X
0
1
0
1
0
1
0
1
EN
0
1
1
1
1
1
1
1
1
On Switch
None
1
2
3
4
5
6
7
8
X = don’t care.
Table 3.
Truth Table
A1
X
0
0
1
1
1
A0
X
0
1
0
1
EN
0
1
1
1
1
On Switch Pair
None
1
2
3
4
X = don’t care.
Rev. F | Page 4 of 20