ADG46+1/ADG46+3
Parameter
25°C
−40°C to +85°C Unit
Test Conditions/Comments
RL = 50 Ω, CL = 35 pF
VS1 = VS2 = 8 V; see Figure 26
VS = 9 V to 15 V, RL = 300 Ω, CL = 35 pF
VS = 9 V to 15 V, RL = 300 Ω, CL = 35 pF
Break-Before-Make Time Delay, tD
(ADG4613 Only)
Fault Response Time
Fault Recovery Time
Threshold Voltage, VT
Charge Injection
Off Isolation
1±
ns typ
11
ns min
ns typ
μs typ
V typ
250
1.4
1.8
292
−56
−±4
0.26
pC typ
dB typ
dB typ
% typ
VS = 6 V, RS = 0 Ω, CL = 1 nF; see Figure 2±
RL = 50 Ω, CL = 5 pF, f = 1 MHz; see Figure 28
RL = 50 Ω, CL = 5 pF, f = 1 MHz; see Figure 29
RL = 110 Ω, 6 V p-p, f = 20 Hz to 20 kHz; see
Figure 31
Channel-to-Channel Crosstalk
Total Harmonic Distortion + Noise, THD + N
Insertion Loss
−3 dB Bandwidth
CS (Off)
−0.2±
250
11.5
11.5
48
dB typ
MHz typ
pF typ
pF typ
pF typ
RL = 50 Ω, CL = 5 pF; f = 1 MHz; see Figure 30
RL = 50 Ω, CL = 5 pF; see Figure 30
VS = 0 V, f = 1 MHz
VS = 0 V, f = 1 MHz
VS = 0 V, f = 1 MHz
CD (Off)
CD (On), CS (On)
POWER REQUIREMENTS
Normal Mode
IDD
VDD = 13.2 V, VSS = 0 V
Digital inputs = 0 V or VDD
90
μA typ
μA max
μA typ
μA max
140
600
660
165
900
IDD
Digital inputs = 5 V
Isolation Mode
IDD
VDD = 13.2 V, VSS = 0 V or floating
VS = 16 V or 1 V
90
μA typ
140
165
μA max
Digital inputs = 0 V or VDD
1 Guaranteed by design, not subject to production test.
Rev. 0 | Page 6 of 24