 浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第14页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第15页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第16页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第17页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第19页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第20页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第21页浏览型号ADF4106BRUZ-R7的Datasheet PDF文件第22页  
ADF4106  
Data Sheet  
Charge Pump Currents  
Do an N (A, B) load (01 in two LSBs).  
CPI3, CPI2, and CPI1 program Current Setting 1 for the charge  
pump. CPI6, CPI5, and CPI4 program Current Setting 2 for the  
charge pump. The truth table is given in Table 9.  
When the initialization latch is loaded, the following occurs:  
The function latch contents are loaded.  
An internal pulse resets the R, N (A, B), and timeout counters  
to load-state conditions and also three-states the charge  
pump. Note that the prescaler band gap reference and the  
oscillator input buffer are unaffected by the internal reset  
pulse, allowing close phase alignment when counting  
resumes.  
Prescaler Value  
P2 and P1 in the function latch set the prescaler values. The  
prescaler value should be chosen so that the prescaler output  
frequency is always less than or equal to 325 MHz. Therefore,  
with an RF frequency of 4 GHz, a prescaler value of 16/17 is  
valid, but a value of 8/9 is not valid.  
Latching the first N (A, B) counter data after the initialization  
word activates the same internal reset pulse. Successive N (A,  
B) loads will not trigger the internal reset pulse, unless there  
is another initialization.  
PD Polarity  
This bit sets the phase detector polarity bit. See Table 9.  
CP Three-State  
CE PIN METHOD  
This bit controls the CP output pin. With the bit set high, the  
CP output is put into three-state. With the bit set low, the CP  
output is enabled.  
Apply VDD  
.
Bring CE low to put the device into power-down. This is an  
asychronous power-down in that it happens immediately.  
THE INITIALIZATION LATCH  
Program the function latch (10).  
Program the R counter latch (00).  
Program the N (A, B) counter latch (01).  
When C2 and C1 = 1 and 1, respectively, the initialization latch  
is programmed. This is essentially the same as the function  
latch (programmed when C2 and C1 = 1 and 0, respectively).  
However, when the initialization latch is programmed, there is  
an additional internal reset pulse applied to the R and N (A, B)  
counters. This pulse ensures that the N (A, B) counter is at the  
load point when the N (A, B) counter data is latched and the  
device begins counting in close phase alignment.  
Bring CE high to take the device out of power-down. The R  
and N (A, B) counters now resume counting in close  
alignment.  
Note that after CE goes high, a 1 µs duration may be required  
for the prescaler band gap voltage and oscillator input buffer  
bias to reach steady state.  
If the latch is programmed for synchronous power-down (CE  
pin is high, PD1 bit is high, and PD2 bit is low), the internal  
pulse also triggers this power-down. The prescaler reference  
and the oscillator input buffer are unaffected by the internal  
reset pulse; therefore, close phase alignment is maintained when  
counting resumes.  
CE can be used to power the device up and down to check for  
channel activity. The input register does not need to be  
reprogrammed each time the device is disabled and enabled as  
long as it is programmed at least once after VDD is initially  
applied.  
When the first N (A, B) counter data is latched after  
initialization, the internal reset pulse is again activated.  
However, successive N (A, B) counter loads after this will not  
trigger the internal reset pulse.  
COUNTER RESET METHOD  
Apply VDD  
.
Do a function latch load (10 in two LSBs). As part of this,  
load 1 to the F1 bit. This enables the counter reset.  
Device Programming After Initial Power-Up  
After initial power up of the device, there are three methods for  
programming the device: initialization latch, CE pin, and  
counter reset.  
Do an R counter load (00 in two LSBs).  
Do an N (A, B) counter load (01 in two LSBs).  
Do a function latch load (10 in two LSBs). As part of this,  
load 0 to the F1 bit. This disables the counter reset.  
Initialization Latch Method  
Apply VDD  
.
This sequence provides the same close alignment as the  
initialization method. It offers direct control over the internal  
reset. Note that counter reset holds the counters at load point  
and three-states the charge pump but does not trigger  
synchronous power-down.  
Program the initialization latch (11 in two LSBs of input  
word). Make sure that the F1 bit is programmed to 0.  
Do a function latch load (10 in two LSBs of the control  
word), making sure that the F1 bit is programmed to a 0.  
Do an R load (00 in two LSBs).  
Rev. E | Page 18 of 24  
 