ADE7759  
PIN CONFIGURATION  
1
2
20  
19  
18  
17  
16  
15  
14  
13  
12  
RESET  
DIN  
DV  
AV  
DOUT  
SCLK  
CS  
DD  
DD  
3
4
V1P  
V1N  
5
ADE7759  
TOPVIEW  
(Not to Scale)  
CLKOUT  
CLKIN  
IRQ  
6
V2N  
7
V2P  
8
AGND  
SAG  
ZX  
9
REF  
IN/OUT  
10  
DGND  
11 CF  
PIN FUNCTION DESCRIPTIONS  
Pin No.  
Mnemonic  
Description  
1
RESET  
Reset Pin for the ADE7759. A logic low on this pin will hold the ADCs and digital circuitry  
(including the serial interface) in a reset condition.  
2
3
DVDD  
AVDD  
Digital Power Supply. This pin provides the supply voltage for the digital circuitry in the ADE7759.  
The supply voltage should be maintained at 5 V 5% for specified operation. This pin should be  
decoupled to DGND with a 10 µF capacitor in parallel with a ceramic 100 nF capacitor.  
Analog Power Supply. This pin provides the supply voltage for the analog circuitry in the ADE7759.  
The supply should be maintained at 5 V 5% for specified operation. Every effort should be made  
to minimize power supply ripple and noise at this pin by the use of proper decoupling method.  
This pin should be decoupled to AGND with a 10 µF capacitor in parallel with a ceramic 100 nF  
capacitor.  
4, 5  
V1P, V1N  
Analog Inputs for Channel 1. This channel is intended for use with the di/dt current transducers  
such as Rogowski coil, or other current sensors such as shunt or current transformer (CT). These  
inputs are fully differential voltage inputs with maximum differential input signal levels of 0.5 V,  
0.25 V and 0.125 V, depending on the full scale selection—See Analog Inputs section. Channel  
1 also has a PGA with gain selections of 1, 2, 4, 8, or 16. The maximum signal level at these pins  
with respect to AGND is 0.5 V. Both inputs have internal ESD protection circuitry. In addition,  
an overvoltage of 6 V can be sustained on these inputs without risk of permanent damage.  
6, 7  
V2N, V2P  
AGND  
Analog Inputs for Channel 2. This channel is intended for use with the voltage transducer. These inputs  
are fully differential voltage inputs with a maximum differential signal level of 0.5 V. Channel 2  
also has a PGA with gain selections of 1, 2, 4, 8, or 16. The maximum signal level at these pins  
with respect to AGND is 0.5 V. Both inputs have internal ESD protection circuitry, and an over-  
voltage of 6 V can be sustained on these inputs without risk of permanent damage.  
8
This pin provides the ground reference for the analog circuitry in the ADE7759, i.e., ADCs and  
reference. This pin should be tied to the analog ground plane or the quietest ground reference in  
the system. This quiet ground reference should be used for all analog circuitry, e.g., antialiasing  
filters, current and voltage transducers, etc. In order to keep ground noise around the ADE7759  
to a minimum, the quiet ground plane should be connected to the digital ground plane at only  
one point. It is acceptable to place the entire device on the analog ground plane—see Application  
Information section.  
9
REFIN/OUT  
DGND  
This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal  
value of 2.4 V 8% and a typical temperature coefficient of 20 ppm/°C. An external reference  
source may be connected at this pin. In either case this pin should be decoupled to AGND with  
a 1 µF capacitor in parallel with a 100 nF capacitor.  
This provides the ground reference for the digital circuitry in the ADE7759, i.e., multiplier, filters,  
and frequency output (CF). Because the digital return currents in the ADE7759 are small, it is  
acceptable to connect this pin to the analog ground plane of the system—see Application Information  
section. However, high bus capacitance on the DOUT pin may result in noisy digital current that  
affects performance.  
10  
11  
CF  
Calibration Frequency Logic Output. The CF logic output gives Active Power information. This  
output is intended to be used for operational and calibration purposes. The full-scale output fre-  
quency can be adjusted by writing to the APGAIN, CFNUM and CFDEN Registers—see Energy  
to Frequency Conversion section.  
–7–  
REV. 0