AD8628/AD8629/AD8630
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameters
Supply Voltage
Input Voltage
Differential Input Voltage
Output Short-Circuit Duration to GND
Storage Temperature Range
R, RM, RU, RT, UJ Packages
Operating Temperature Range
Junction Temperature Range
R, RM, RU, RT, UJ Packages
Lead Temperature Range
(Soldering, 60 sec)
1
Ratings
6V
GND − 0.3 V to V
S−
+ 0.3 V
±5.0 V
Indefinite
−65°C to +150°C
−40°C to +125°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 4. Thermal Characteristics
−65°C to +150°C
300°C
Package Type
5-Lead TSOT-23 (UJ-5)
5-Lead SOT-23 (RT-5)
8-Lead SOIC_N (R-8)
8-Lead MSOP (RM-8)
14-Lead SOIC_N (R-14)
14-Lead TSSOP (RU-14)
1
Differential input voltage is limited to ±5 V or the supply voltage, whichever
is less.
θ
JA 1
207
230
158
190
105
148
θ
JC
61
146
43
44
43
23
Unit
°C/W
°C/W
°C/W
°C/W
°C/W
°C/W
θ
JA
is specified for worst-case conditions, that is, θ
JA
is specified for the device
soldered in a circuit board for surface-mount packages. This was measured
using a standard 2-layer board.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. E | Page 6 of 24