 浏览型号AD8052ARMZ的Datasheet PDF文件第15页浏览型号AD8052ARMZ的Datasheet PDF文件第16页浏览型号AD8052ARMZ的Datasheet PDF文件第17页浏览型号AD8052ARMZ的Datasheet PDF文件第18页浏览型号AD8052ARMZ的Datasheet PDF文件第20页浏览型号AD8052ARMZ的Datasheet PDF文件第21页浏览型号AD8052ARMZ的Datasheet PDF文件第22页浏览型号AD8052ARMZ的Datasheet PDF文件第23页  
AD8051/AD8052/AD8054
LAYOUT CONSIDERATIONS
The specified high speed performance of the AD8051/AD8052/
AD8054 requires careful attention to board layout and component
selection. Proper RF design techniques and low parasitic
component selection are necessary.
The PCB should have a ground plane covering all unused
portions of the component side of the board to provide a low
impedance path. The ground plane should be removed from the
area near the input pins to reduce parasitic capacitance.
Chip capacitors should be used for supply bypassing. One end
should be connected to the ground plane and the other within
3 mm of each power pin. An additional large (4.7 μF to 10 μF)
tantalum electrolytic capacitor should be connected in parallel,
but not necessarily so close, to supply current for fast, large
signal changes at the output.
The feedback resistor should be located close to the inverting
input pin to keep the parasitic capacitance at this node to a
minimum. Parasitic capacitance of less than 1 pF at the inverting
input can significantly affect high speed performance.
Stripline design techniques should be used for long signal traces
(greater than about 25 mm). These should be designed with a
characteristic impedance of 50 Ω or 75 Ω and be properly
terminated at each end.
GAIN (dB)
noise bandwidth of the analog signal before analog-to-digital
conversion.
Note that the unused amplifier’s inputs should be tied to ground.
R6
1kΩ
C1
50pF
R2
2kΩ
2
1
3
13
14
12
V
IN
R1
3kΩ
R4
2kΩ
R3
2kΩ
6
7
5
10
C2
50pF
R5
2kΩ
9
8
AD8054
BAND-PASS
FILTER OUTPUT
Figure 46. 2 MHz Biquad Band-Pass Filter Using AD8054
The frequency response of the circuit is shown in Figure 47.
0
–10
–20
–30
ACTIVE FILTERS
Active filters at higher frequencies require wider bandwidth op
amps to work effectively. Excessive phase shift produced by
lower frequency op amps can significantly affect active filter
performance.
that uses three op amps of an AD8054. Such circuits are
sometimes used in medical ultrasound systems to lower the
–40
10k
100k
1M
FREQUENCY (Hz)
10M
100M
01062-047
Figure 47. Frequency Response of 2 MHz Band-Pass Biquad Filter
Rev. J | Page 18 of 24
01062-046
AD8054
AD8054