AD7714  
CH2–CH0  
Channel Select. These three bits select a channel either for conversion or for access to calibration coefficients as  
outlined in Table VII. There are three pairs of calibration registers on the part. In fully differential mode, the part  
has three input channels so each channel has its own pair of calibration registers. In pseudo-differential mode, the  
AD7714 has five input channels with some of the input channel combinations sharing calibration registers. With  
CH2, CH1 and CH0 at a logic 1, the part looks at the AIN6 input internally shorted to itself. This can be used as  
a test method to evaluate the noise performance of the part with no external noise sources. In this mode, the AIN6  
input should be connected to an external voltage within the allowable common-mode range for the part. The  
Power-On or RESET status of these bits is 1,0,0 selecting the differential pair AIN1 and AIN2.  
2
Table VII. Channel Selection  
CH2  
CH1  
CH0  
AIN(+)  
AIN(–)  
Type  
Calibration Register Pair  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
AIN1  
AIN2  
AIN3  
AIN4  
AIN1  
AIN3  
AIN5  
AIN6  
AIN6  
AIN6  
AIN6  
AIN6  
AIN2  
AIN4  
AIN6  
AIN6  
Pseudo Differential  
Pseudo Differential  
Pseudo Differential  
Pseudo Differential  
Fully Differential  
Fully Differential  
Fully Differential  
Test Mode  
Register Pair 0  
Register Pair 1  
Register Pair 2  
Register Pair 2  
Register Pair 0  
Register Pair 1  
Register Pair 2  
Register Pair 2  
Mode Register (RS2-RS0 = 0, 0, 1); Power On/Reset Status: 00 Hex  
The Mode Register is an eight bit register from which data can either be read or to which data can be written. Table VIII outlines the  
bit designations for the Mode Register.  
Table VIII. Mode Register  
MD2  
MD1  
MD0  
G2  
G1  
G0  
BO  
FSYNC  
MD2  
MD1  
MD0  
Operating Mode  
0
0
0
Normal Mode; this is the normal mode of operation of the device whereby the device is performing nor-  
mal conversions. This is the default condition of these bits after Power-On or RESET.  
0
0
0
0
1
0
1
Self-Calibration; this activates self-calibration on the channel selected by CH2, CH1 and CH0 of the  
Communications Register. This is a one step calibration sequence and when complete the part returns to  
Normal Mode with MD2, MD1 and MD0 returning to 0, 0, 0. The DRDY output or bit goes high when  
calibration is initiated and returns low when this self-calibration is complete and a new valid word is  
available in the data register. The zero-scale calibration is performed at the selected gain on internally  
shorted (zeroed) inputs and the full-scale calibration is performed at the selected gain on an internally-  
generated VREF/Selected Gain.  
1
1
Zero-Scale System Calibration; this activates zero scale system calibration on the channel selected by  
CH2, CH1 and CH0 of the Communications Register. Calibration is performed at the selected gain on  
the input voltage provided at the analog input during this calibration sequence. This input voltage should  
remain stable for the duration of the calibration. The DRDY output or bit goes high when calibration is  
initiated and returns low when this zero-scale calibration is complete and a new valid word is available in  
the data register. At the end of the calibration, the part returns to Normal Mode with MD2, MD1 and  
MD0 returning to 0, 0, 0.  
Full-Scale System Calibration; this activates full-scale system calibration on the selected input channel.  
Calibration is performed at the selected gain on the input voltage provided at the analog input during this  
calibration sequence. This input voltage should remain stable for the duration of the calibration. Once  
again, the DRDY output or bit goes high when calibration is initiated and returns low when this full-scale  
calibration is complete and a new valid word is available in the data register. At the end of the calibration,  
the part returns to Normal Mode with MD2, MD1 and MD0 returning to 0, 0, 0.  
REV. C  