 浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第22页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第23页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第24页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第25页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第27页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第28页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第29页浏览型号AD7705BRUZ-REEL7的Datasheet PDF文件第30页  
AD7705/AD7706  
For a full system calibration, the zero-scale point must be  
presented to the converter first. It must be applied to the  
converter before the calibration step is initiated and remain  
stable until the step is complete. Once the zero-scale voltage is  
set up, a zero-scale system calibration is initiated by writing the  
appropriate values (1, 0) to the MD1 and MD0 bits of the setup  
register. The zero-scale system calibration is performed at the  
selected gain. The duration of the calibration is 3 × 1/output  
rate. Then, Bit MD1 and Bit MD0 in the setup register return to  
0, 0, providing the earliest indication that the calibration  
The fact that the system calibration involves two steps offers  
another feature. After the sequence of a full system calibration is  
complete, additional offset or gain calibrations can be performed  
individually to adjust the system zero reference point or the  
system gain. Calibrating one of the parameters, either system  
offset or system gain, does not affect the other parameter.  
When the part is used in unbuffered mode, system calibration  
can be used to remove errors from source impedances on the  
analog input. A simple R-C antialiasing filter on the front end  
can introduce a gain error on the analog input voltage, but the  
system calibration can be used to remove this error.  
DRDY  
sequence is complete. The  
line goes high when calibration  
is initiated and returns low when there is a valid new word in the  
data register. The duration time from the calibration command  
Span and Offset Limits  
DRDY  
being issued to  
the part performs a normal conversion on the AIN voltage before  
goes low.  
going low is 4 × 1/output rate, because  
Whenever the system calibration mode is used, there are limits  
on the amount of offset and span that can be accommodated.  
The overriding requirement for determining the amount of  
offset and gain that can be accommodated by the part is that the  
positive full-scale calibration limit is < 1.05 × VREF/gain. This  
allows the input range to go 5ꢀ above the nominal range. The  
built-in headroom in the AD7705/AD7706 analog modulator  
ensures that the parts operate correctly with a positive full-scale  
voltage that is 5ꢀ beyond the nominal.  
DRDY  
If  
is low before (or goes low during) writing the  
DRDY  
calibration command to the setup register, it can take up to one  
DRDY  
modulator cycle (MCLK IN/128) before  
goes high to  
DRDY  
indicate that a calibration is in progress. Therefore,  
should be ignored for one modulator cycle after the last bit is  
written to the setup register in the calibration command.  
The range of input span in both the unipolar and bipolar modes  
has a minimum value of 0.8 × VREF/gain and a maximum value of  
2.1 × VREF/gain. However, when determining the span, which is  
the difference between the bottom and top of the devices’ input  
range, the user must take into account the limitation on the  
positive full-scale voltage. The amount of offset that can be  
accommodated depends on whether the unipolar or bipolar  
mode is used, and the user must also take into account the  
limitation on the positive full-scale voltage. In unipolar mode,  
there is considerable flexibility in handling negative offsets with  
respect to AIN(−) on the AD7705, and with respect to  
COMMON on the AD7706. In both unipolar and bipolar  
modes, the range of positive offsets that can be handled by the  
part depends on the selected span. Therefore, in determining  
the limits for system zero-scale and full-scale calibrations, the  
user must ensure that the offset range plus the span range does  
not exceed 1.05 × VREF/gain.  
After the zero-scale point is calibrated, the full-scale point is  
applied to AIN, and the second step of the calibration process is  
initiated by writing the appropriate values (1, 1) to MD1 and  
MD0. The full-scale voltage must be set up before the calibration  
is initiated and must remain stable throughout the calibration  
step. The full-scale system calibration is performed at the  
selected gain. The duration of the calibration is 3 × 1/output  
rate. Then, the MD1 and MD0 bits in the setup register return  
to 0, 0, providing the earliest indication that the calibration  
DRDY  
sequence is complete. The  
line goes high when calibration  
is initiated and returns low when there is a valid new word in  
the data register. The duration time from the calibration  
DRDY  
command being issued to  
because the part performs a normal conversion on the AIN  
DRDY DRDY  
is low before (or goes  
going low is 4 × 1/output rate,  
voltage before  
goes low. If  
low during) writing the calibration command to the setup  
register, it can take up to one modulator cycle (MCLK IN/128)  
DRDY  
If the part is used in unipolar mode with a required span of  
0.8 × VREF/gain, the offset range that the system calibration can  
handle is –1.05 × VREF/gain to +0.25 × VREF/gain. If  
before  
goes high to indicate that calibration is in  
DRDY  
progress. Therefore,  
should be ignored for one  
modulator cycle after the last bit is written to the setup register  
in the calibration command.  
the part is used in unipolar mode with a required span of  
VREF/gain, the offset range that the system calibration can  
In unipolar mode, the system calibration is performed between  
the two endpoints of the transfer function. In bipolar mode, it is  
performed between midscale (zero differential voltage) and  
positive full scale.  
handle is −1.05 × VREF/gain to +0.05 × VREF/gain. Similarly, if  
the part is used in unipolar mode and required to remove an  
offset of 0.2 × VREF/gain, the maximum span range that the  
system calibration can handle is 0.85 × VREF/gain.  
Rev. C | Page 26 of 44  