AD708
Parameter
OUTPUT VOLTAGE
Conditions
R
LOAD
≥ 10 kΩ
R
LOAD
≥ 2 kΩ
R
LOAD
≥ 1 kΩ
T
MIN
to T
MAX
AD708J/AD708A
Min
Typ Max
13.5
14
12.5
13.0
12.0
12.5
12.0
13.0
60
4.5
135
12
±3
5.5
165
18
±18
Min
13.5
12.5
12.0
12.0
OPEN-LOOP OUTPUT RESISTANCE
POWER SUPPLY
Quiescent Current
Power Consumption
Operating Range
1
AD708B
Typ Max
14.0
13.0
12.5
13.0
60
4.5
135
12
5.5
165
18
±18
Min
13.5
12.5
12.0
12.0
AD708S
Typ Max
14
13
12.5
13
60
4.5
135
12
5.5
165
18
±18
Unit
±V
±V
±V
±V
Ω
mA
mW
mW
V
V
S
= ±15 V
V
S
= ±3 V
±3
±3
All min and max specifications are guaranteed. Specifications in boldface are tested on all production units at final electrical test. Results from those tests are used to
calculate outgoing quality levels.
2
Input offset voltage specifications are guaranteed after five minutes of operation at T
A
= 25°C.
3
Matching is defined as the difference between parameters of the two amplifiers.
Rev. C | Page 4 of 16