欢迎访问ic37.com |
会员登录 免费注册
发布采购

AD6600AST 参数 Datasheet PDF下载

AD6600AST图片预览
型号: AD6600AST
PDF下载: 下载PDF文件 查看货源
内容描述: 双通道,增益范围调整ADC ,带有RSSI [Dual Channel, Gain-Ranging ADC with RSSI]
分类和应用: 转换器模数转换器
文件页数/大小: 24 页 / 305 K
品牌: AD [ ANALOG DEVICES ]
 浏览型号AD6600AST的Datasheet PDF文件第4页浏览型号AD6600AST的Datasheet PDF文件第5页浏览型号AD6600AST的Datasheet PDF文件第6页浏览型号AD6600AST的Datasheet PDF文件第7页浏览型号AD6600AST的Datasheet PDF文件第9页浏览型号AD6600AST的Datasheet PDF文件第10页浏览型号AD6600AST的Datasheet PDF文件第11页浏览型号AD6600AST的Datasheet PDF文件第12页  
AD6600
ABSOLUTE MAXIMUM RATINGS
1
Parameter
ELECTRICAL
AVCC Voltage
DVCC Voltage
Analog Input Voltage
2
Analog Input Current
2
Digital Input Voltage
3
Output Current
4
Resonant Port Voltage
5
ENVIRONMENTAL
Operating Temperature Range
(Ambient)
Maximum Junction Temperature
Lead Temperature (Soldering, 10 sec)
Storage Temperature Range (Ambient)
6
Min Max
0
0
0
0
0
7
7
AVCC
25
AVCC
4
AVCC
Unit
V
V
V
mA
V
mA
V
EXPLANATION OF TEST LEVELS
Test Level
I.
100% Production Tested.
II. 100% Production Tested at 25°C and guaranteed by design
and characterization at temperature extremes.
IV. Parameter is guaranteed by design and characterization
testing.
V. Parameter is a typical value only.
ORDERING GUIDE
–40 +85
150
300
–65 +150
°C
°C
°C
°C
Model
AD6600AST
Temperature Package
Range
Description
–40°C to
+85°C
(Ambient)
Package
Option
NOTES
1
Absolute maximum ratings are limiting values to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability is not necessarily implied. Exposure to absolute maximum rating
conditions for an extended period of time may affect device reliability.
2
Pins AIN,
AIN,
BIN,
BIN.
3
Pins ENC,
ENC,
A_SEL, B_SEL.
4
Pins D10:0, RSSI2:0, AB_OUT, CLK2×.
5
Pins FLT,
FLT.
6
Typical thermal impedance (44-lead LQFP);
θ
JC
= 16°C/W,
θ
JA
= 55°C/W.
AD6600ST/PCB
44-Terminal LQFP ST-44
(Low-Profile Quad
Plastic Flatpack)
Evaluation Board
with AD6600AST
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD6600 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recom-
mended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–8–
REV. 0