ABSOLUTE MAXIMUM RATINGS
1
Parameter
ELECTRICAL
AVCC Voltage
DVCC Voltage
Analog Input Voltage
2
Analog Input Current
2
Digital Input Voltage
3
Output Current
4
Resonant Port Voltage
5
ENVIRONMENTAL
Operating Temperature Range
(Ambient)
Maximum Junction Temperature
Lead Temperature (Soldering, 10 sec)
Storage Temperature Range (Ambient)
6
Min Max
0
0
0
0
0
7
7
AVCC
25
AVCC
4
AVCC
Unit
V
V
V
mA
V
mA
V
EXPLANATION OF TEST LEVELS
Test Level
I.
100% Production Tested.
II. 100% Production Tested at 25°C and guaranteed by design
and characterization at temperature extremes.
IV. Parameter is guaranteed by design and characterization
testing.
V. Parameter is a typical value only.
ORDERING GUIDE
–40 +85
150
300
–65 +150
°C
°C
°C
°C
Model
AD6600AST
Temperature Package
Range
Description
–40°C to
+85°C
(Ambient)
Package
Option
NOTES
1
Absolute maximum ratings are limiting values to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability is not necessarily implied. Exposure to absolute maximum rating
conditions for an extended period of time may affect device reliability.
2
Pins AIN,
AIN,
BIN,
BIN.
3
Pins ENC,
ENC,
A_SEL, B_SEL.
4
Pins D10:0, RSSI2:0, AB_OUT, CLK2×.
5
Pins FLT,
FLT.
6
Typical thermal impedance (44-lead LQFP);
θ
JC
= 16°C/W,
θ
JA
= 55°C/W.
AD6600ST/PCB
44-Terminal LQFP ST-44
(Low-Profile Quad
Plastic Flatpack)
Evaluation Board
with AD6600AST
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD6600 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recom-
mended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–8–
REV. 0