LAYOUT AND GROUNDING
The use of ground planes is recommended to minimize the
impedance of ground returns (and hence, the size of dc errors).
To isolate low level analog signals from a noisy digital environment,
many data acquisition components have separate analog and
digital ground returns (see Figure 47). Return all ground pins
from mixed-signal components, such as analog-to-digital
converters, through the high quality analog ground plane.
Digital ground lines of mixed-signal components should also
be returned through the analog ground plane. This may seem
to break the rule of separating analog and digital grounds;
however, in general, there is also a requirement to keep the
voltage difference between digital and analog grounds on a
converter as small as possible (typically, <0.3 V). The increased
noise, caused by the digital return currents of the converter
flowing through the analog ground plane, is generally negligible.
To maximize isolation between analog and digital, connect the
ground planes back at the supplies.
If there is only one power supply available, it must be shared by
both digital and analog circuitry. Figure 48 shows how to minimize
interference between the digital and analog circuitry. As in the
previous case, use separate analog and digital ground planes or
use reasonably thick traces as an alternative to a digital ground
plane. Connect the ground planes at the ground pin of the power
supply. Run separate traces (or power planes) from the power
supply to the supply pins of the digital and analog circuits. Ideally,
each device should have its own power supply trace, but they
can be shared by multiple devices if a single trace is not used to
route current to both digital and analog circuitry.
ANALOG POWER SUPPLY
+5V
–5V
GND
DIGITAL POWER SUPPLY
GND
+5V
0.1µF
0.1µF
0.1µF
0.1µF
7
2
4
1
6
4
3
6
14
AD627
3
5
V
IN1
V
IN2
V
DD
ADC
AGND
DGND
12
AGND
V
DD
00782-045
AD7892-2
MICRO-
PROCESSOR
Figure 47. Optimal Grounding Practice for a Bipolar Supply Environment with Separate Analog and Digital Supplies
POWER SUPPLY
5V
GND
0.1µF
0.1µF
0.1µF
7
2
4
1
6
4
AD627
3
5
V
IN
V
DD
ADC
AGND
DGND
12
V
DD
DGND
00782-046
AD7892-2
MICRO-
PROCESSOR
Figure 48. Optimal Ground Practice in a Single-Supply Environment
Rev. D | Page 20 of 24