AD590
AD590L AND AD590M SPECIFICATIONS
25°C and V
S
= 5 V, unless otherwise noted.
Table 2.
Parameter
POWER SUPPLY
Operating Voltage Range
OUTPUT
Nominal Current Output @ 25°C (298.2 K)
Nominal Temperature Coefficient
Calibration Error @ 25°C
Absolute Error (Over Rated Performance Temperature Range)
Without External Calibration Adjustment
With ± 25°C Calibration Error Set to Zero
Nonlinearity
Repeatability
Long-Term Drift
Current Noise
Power Supply Rejection
4 V ≤ V
S
≤ 5 V
5 V ≤ V
S
≤ 15 V
15 V ≤ V
S
≤ 30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical Turn-On Time
Reverse Bias Leakage Current (Reverse Voltage = 10 V)
1
Data Sheet
Min
4
AD590L
Typ
Max
30
298.2
1
±1.0
±3.0
±1.6
±0.4
±0.1
±0.1
40
0.5
0.2
0.1
10
10
100
20
10
Min
4
AD590M
Typ
Max
30
298.2
1
±0.5
±1.7
±1.0
±0.3
±0.1
±0.1
40
0.5
0.2
0.1
10
10
100
20
10
Unit
V
μA
μA/K
°C
°C
°C
°C
°C
°C
°C
pA/√Hz
μA/V
μA/V
μA/V
Ω
pF
μs
pA
Specifications shown in
boldface
are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All
minimum and maximum specifications are guaranteed, although only those shown in
boldface
are tested on all production units.
2
Maximum deviation between +25°C readings after temperature cycling between −55°C and +150°C; guaranteed, not tested.
3
Conditions: constant 5 V, constant 125°C; guaranteed, not tested.
4
Leakage current doubles every 10°C.
°K
°C
+223°
–50°
+273° +298° +323°
0°
+25°
+50°
+373°
+100°
+423°
+150°
°F –100°
0°
+32°
+100°
+70°
+200°
+212°
+300°
C
½
5
F
32
K
½
C
273.15
9
9
F
½
C
32
R
½
F
459.7
5
Figure 5. Temperature Scale Conversion Equations
Rev. G | Page 4 of 16
00533-002