AD586
SPECIFICATIONS
AD586J, AD586K/AD586A, AD586L/AD586B
@ T
A
= 25°C, V
IN
= 15 V, unless otherwise noted. Specifications in
boldface
are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in
boldface
are tested on all production units, unless otherwise specified.
Table 1.
Parameter
OUTPUT VOLTAGE
OUTPUT VOLTAGE
DRIFT
0°C to 70°C
−55°C to +125°C
GAIN ADJUSTMENT
LINE REGULATION
10.8 V < + V
IN
< 36 V
T
MIN
to T
MAX
11.4 V < +V
IN
< 36 V
T
MIN
to T
MAX
LOAD REGULATION
Sourcing 0 mA < I
OUT
< 10 mA
25°C
T
MIN
to T
MAX
Sinking −10 mA < I
OUT
< 0 mA
25°C
QUIESCENT CURRENT
POWER CONSUMPTION
OUTPUT NOISE
0.1 Hz to 10 Hz
Spectral Density, 100 Hz
LONG-TERM STABILITY
SHORT-CIRCUIT
CURRENT-TO-GROUND
TEMPERATURE RANGE
Specified Performance
Operating Performance
1
2
Min
4.980
AD586J
Typ
Max
5.020
AD586K/AD586A
Min
Typ
Max
4.995
5.005
AD586L/AD586B
Min
Typ
Max
4.9975
5.0025
Unit
V
25
+6
−2
+6
−2
15
+6
−2
5
ppm/°C
ppm/°C
%
%
±100
±100
±100
µV/V
µV/V
100
100
400
3
100
100
400
3
100
100
400
3
µV/mA
µV/mA
µV/mA
mA
mW
µV p-p
nV/√Hz
ppm/1000 hr
2
30
4
100
15
45
0
−40
2
30
4
100
15
2
30
4
100
15
60
70
+85
0
−40
−40
45
(K grade)
(A grade)
60
70
+85
+85
0
−40
−40
45
(L grade)
(B grade)
60
70
+85
+85
mA
°C
°C
°C
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
Lower row shows specified performance for A and B grades.
3
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.