ABSOLUTE MAXIMUM RATINGS
Table 9. T
A
= 25°C, unless otherwise noted
Parameter
AV
DD
to AGND
DV
DD
to DGND
Digital Inputs to DGND
SDA/SCL to DGND
Digital Outputs to DGND
REFIN/REFOUT to AGND
AGND to DGND
VOUTx to AGND
Analog Inputs to AGND
MON_IN Inputs to AGND
MON_OUT to AGND
Operating Temperature Range
Commercial (B Version)
Storage Temperature Range
JunctionTemperature (T
J
Max)
100-lead LQFP Package
θ
JA
Thermal Impedance
Reflow Soldering
Peak Temperature
Rating
–0.3 V to +7 V
–0.3 V to +7 V
–0.3 V to DV
DD
+ 0.3 V
–0.3 V to + 7 V
–0.3 V to DV
DD
+ 0.3 V
–0.3 V to AV
DD
+ 0.3 V
–0.3 V to +0.3 V
–0.3 V to AV
DD
+ 0.3 V
–0.3 V to AV
DD
+ 0.3 V
–0.3 V to AV
DD
+ 0.3 V
–0.3 V to AV
DD
+ 0.3 V
–40°C to +85°C
–65°C to +150°C
150°C
44°C/W
230°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
1
Transient currents of up to 100 mA will not cause SCR latch-up
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
this product features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.