TABLE IIA. Electrical test requirements.
Subgroups
Test requirements
Subgroups
(in accordance with
(in accordance with
MIL-STD-883,
MIL-PRF-38535, table III)
method 5005, table I)
Device
Device
class Q
Device
class V
class M
1
Interim electrical
1
1
parameters (see 4.2)
Final electrical
1, 2, 3, 4, 5, 1/
6, 7, 8A
1, 2, 3, 4, 1/
5, 6, 7, 8A
1, 2, 3, 1/ 2/
4, 5, 6, 7, 8A
1, 2, 3, 4, 3/
parameters (see 4.2)
1, 2, 3, 4, 5, 6, 3/
7, 8A, 9, 10
1, 2, 3, 4, 3/
Group A test
5, 6, 7, 8A, 9,
10
5, 6, 7, 8A,
9, 10
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
1,4
1,4
---
1,4
1,4
---
1,4 2/
Group D end-point electrical
parameters (see 4.4)
1,4
Group E end-point electrical
parameters (see 4.4)
---
1/ PDA applies to subgroup 1. Exclude delta from PDA. (V
for device 01 and 03)
and I
excluded from PDA
OS
OS
2/ See table IIB for delta measurement parameters.
3/ Subgroup 10, if not tested, shall be guaranteed to the limits specified in table I herein.
Table IIB. 240 hour burn-in and group C end-point electrical parameters.
Parameter
Device type
03
Limit
Delta
0.5 mV
±0.5 mV
V
OS
IB
±50 pA
±40 pA
I
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified. Quality conformance inspection for device
class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed for
device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a. Tests shall be as specified in table IIA herein.
b. Subgroup 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
SIZE
STANDARD
5962-89542
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
E
SHEET
COLUMBUS, OHIO 43218-3990
9