TABLE I. Electrical performance characteristics.
Conditions
-55°C ≤ TA ≤ +125°C
VCC = +15 V, VLOG = +5 V,
Group A
subgroups
Device
type
Limits
Unit
mA
Test
Symbol
VEE = -15 V 1/
unless otherwise specified
Min
Max
40
ILOG
1, 2, 3
01, 02,
03, 04
01, 02
Power supply current
From VLOG
M, D, P, L, R
M, D, P, L, R
1
40
1
05, 06,
07, 08
1, 2, 3
ICC
1, 2, 3
1
01, 02
01, 02
03, 04
5
5
mA
mA
Power supply current
From VCC
1, 2, 3
15
05, 06,
07, 08
9
IEE
1, 2, 3
01, 02,
03, 04
01, 02
-30
Power supply current
From VEE
M, D, P, L, R
1
-30
0
05, 06,
07, 08
1, 2, 3
1, 2, 3
All
All
12
Bits
Resolution
ILE
1
2, 3
1
-0.5
-1.0
-1.5
0.5
1.0
1.5
LSB
Integral linearity error
M, D, P, L, R
01, 02
All
Differential linearity error
(minimum resolution for
which no missing codes
DLE
VIO
1
12
12
Bits
2, 3
guaranteed)
2/
1
All
01, 02
01
-2.0
-3.0
-1.0
-1.0
2.0
3.0
1.0
1.0
LSB
TA = +25°C
Unipolar offset voltage error
M, D, P, L, R
1
12
Using internal reference
1, 2, 3 3/
2, 3
01, 02
03, 04
05, 06
07, 08
All
LSB
∆VIO
∆T
Unipolar offset drift
2/
BZ
1
-4.0
-5.0
-2.0
-1.0
4.0
5.0
2.0
1.0
LSB
LSB
TA = +25°C
Bipolar offset voltage error
M, D, P, L, R
1
12
01, 02
01
Using internal reference
1, 2, 3 3/
2, 3
01
∆BZ
Bipolar zero offset drift
2/
T
03,
05, 07
02
1, 2, 3 3/
2, 3
-2.0
2.0
04,
06, 08
See footnotes at end of table.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-85127
A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
REVISION LEVEL
J
SHEET
6
DSCC FORM 2234
APR 97