 浏览型号5962R9468002V2A的Datasheet PDF文件第3页浏览型号5962R9468002V2A的Datasheet PDF文件第4页浏览型号5962R9468002V2A的Datasheet PDF文件第5页浏览型号5962R9468002V2A的Datasheet PDF文件第6页浏览型号5962R9468002V2A的Datasheet PDF文件第8页浏览型号5962R9468002V2A的Datasheet PDF文件第9页浏览型号5962R9468002V2A的Datasheet PDF文件第10页浏览型号5962R9468002V2A的Datasheet PDF文件第11页  
TABLE I. Electrical performance characteristics - Continued.  
Conditions 1/ 2/ 3/  
-55C T +125C  
unless otherwise specified  
Test  
Symbol  
Group A  
subgroups  
Device  
type  
Limits 4/  
Unit  
A
Min  
Max  
1
01  
1000  
800  
500  
1000  
100  
100  
800  
600  
V/mV  
A
VO  
V
= 10 V, R 2 k  
L
Large signal voltage gain  
OUT  
OUT  
OUT  
OUT  
V
V
V
= 10 V, R 600   
L
2,3  
1
= 10 V, R 2 k  
L
02, 03  
02  
= 10 V, R 2 k  
L
M,D,P,L,R  
M,D,P,L  
1
1
03  
1
02, 03  
V
V
= 10 V, R 600   
L
OUT  
2,3  
= 10 V, R 2 k  
OUT  
L
1/ Device 02 supplied to this drawing have been characterized through all levels M, D, P, L, R of irradiation.  
Device 03 supplied to this drawing have been characterized through all levels P and L of irradiation.  
However, device 02 is only tested at the “R” level and device type 03 is only tested at the “L” level. Pre and Post irradiation  
values are identical unless otherwise specified in Table I. When performing post irradiation electrical measurements for  
any RHA level, T = +25C.  
A
2/ Unless otherwise specified, V = 15 V and source resistance (R ) = 50 .  
S
S
3/ The 02 device may be low dose rate sensitive in a space environment and may demonstrate enhanced low dose rate  
effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in  
MIL-STD-883, method 1019, condition A for device type 02. Device type 03, has been tested at low dose rate.  
4/ The algebraic convention, whereby the most negative value is a minimum and the most positive is a maximum, is used  
in this table. Negative current shall be defined as conventional current flow out of a device terminal.  
5/ This parameter is not tested post-irradiation.  
6/ Input voltage range is defined as the V  
range used for the CMRR test.  
CM  
7/ This test shall be 100% tested at preburn-in of interim electrical parameters and guaranteed to the limits specified in  
table I herein.  
SIZE  
STANDARD  
5962-94680  
A
MICROCIRCUIT DRAWING  
DLA LAND AND MARITIME  
REVISION LEVEL  
E
SHEET  
COLUMBUS, OHIO 43218-3990  
7
DSCC FORM 2234  
APR 97