 浏览型号5962R8964401VPA的Datasheet PDF文件第3页浏览型号5962R8964401VPA的Datasheet PDF文件第4页浏览型号5962R8964401VPA的Datasheet PDF文件第5页浏览型号5962R8964401VPA的Datasheet PDF文件第6页浏览型号5962R8964401VPA的Datasheet PDF文件第8页浏览型号5962R8964401VPA的Datasheet PDF文件第9页浏览型号5962R8964401VPA的Datasheet PDF文件第10页浏览型号5962R8964401VPA的Datasheet PDF文件第11页  
TABLE I. Electrical performance characteristics – Continued.  
Conditions 1/ 2/  
-55°C T +125°C  
Test  
Symbol  
Group A  
subgroups  
Device  
type  
Limits 3/  
Unit  
A
±V = ±15 V  
S
unless otherwise specified  
5 V to 18 V 5/ 8/ 9/  
Min  
Max  
Input bias current versus  
supply  
4
5,6  
4
01, 02  
01, 02  
150  
200  
250  
300  
150  
nA/V  
+TC  
S
-TC  
S
5,6  
4
Input bias current versus  
common-mode  
nA/V  
+TC  
V = ±10 V 5/ 6/ 8/  
CM  
CM  
5,6  
4
200  
160  
200  
-TC  
CM  
5,6  
Common-mode rejection  
ratio  
CMRR  
4,5,6  
01, 02  
35  
µV/V  
V
CM  
= ±10 V 5/ 8/  
1/ Device type 01 supplied to this drawing has been characterized through all levels P, L, and R of irradiation.  
Device type 02 supplied to this drawing has been characterized through level “L” of irradiation.  
However, device type 01, is only tested at the “R” level and device type 02 is only tested at the ”L” level. Pre and Post  
irradiation values are identical unless otherwise specified in table I. When performing post irradiation electrical  
measurements for any RHA level, T = +25°C.  
A
2/ Device type 01 may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect.  
Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883,  
method 1019, condition A for device type 01 and condition D for device type 02. Device type 02 is tested at low dose rate.  
3/ The magnitude convention is used to establish the limits for these tests.  
4/ Input offset voltage parameters are guaranteed after the equivalent of five minutes at T = +25°C.  
A
5/ This parameter is not tested post irradiation.  
6/ Bias current parameters are guaranteed maximum after the equivalent of five minutes at T = +25°C.  
A
7/ This parameter is guaranteed by testing common-mode rejection ratio.  
8/ Guaranteed, if not tested, to the limits specified in table I herein.  
9/ Test conditions are as follows, when +V = +15 V, -V = -5 V to –18 V, and when –V = -15 V, +V = +5 V to +18 V.  
S
S
S
S
SIZE  
STANDARD  
5962-89644  
A
MICROCIRCUIT DRAWING  
DLA LAND AND MARITIME  
REVISION LEVEL  
SHEET  
COLUMBUS, OHIO 43218-3990  
D
7
DSCC FORM 2234  
APR 97