TABLE IIA. Electrical test requirements.
Subgroups
(in accordance with
MIL-STD-883,
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Test requirements
method 5005, table I)
Device
class M
Device
class Q
Device
class V
Interim electrical
parameters (see 4.2)
1
1
1
1,2,3,4, 1/ 2/
5,6
Final electrical
parameters (see 4.2)
1,2,3,4,5,6 1/
1,2,3,4,5,6 1/
Group A test
requirements (see 4.4)
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
Group C end-point electrical
parameters (see 4.4)
1
1
1 2/
1
Group D end-point electrical
parameters (see 4.4)
1
1
Group E end-point electrical
parameters (see 4.4)
---
---
1, 4
1/ PDA applies to subgroup 1.
2/ Delta limits as specified in table IIB shall be required where specified, and the delta limits
shall be computed with reference to the previous interim electrical parameters.
TABLE IIB. Burn-in and operating life test delta parameters. T = +25C. 1/ 2/
A
Limit
Delta
Parameter
Device types
Min
Max
Min
Max
100 V
250 V
5 nA
01, 03
02, 04
01, 03
02, 04
01, 03
02, 04
0.4 mV
0.8 mV
10 nA
10 nA
25 nA
25 nA
V
OS
I
I
OS
5 nA
5 nA
B
5 nA
1/ Deltas are performed at room temperature.
2/ 240 hour burn-in and 1,000 hour operating group C life test.
SIZE
STANDARD
5962-88565
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
H
9
DSCC FORM 2234
APR 97