(typical at 25
؇
C unless otherwise noted)
AD2S80A–SPECIFICATIONS
Parameter
Conditions
Min
Typ
Max
Unit
RATIO MULTIPLIER
AC Error Output Scaling
10 Bit
12 Bit
14 Bit
16 Bit
177.6
44.4
mV/Bit
mV/Bit
mV/Bit
mV/Bit
11.1
2.775
PHASE SENSITIVE DETECTOR
Output Offset Voltage
Gain
In Phase
In Quadrature
Input Bias Current
Input Impedance
Input Voltage
12
mV
w.r.t. REF
w.r.t. REF
–0.882
1
–0.9
60
–0.918
0.02
150
V rms/V dc
V rms/V dc
nA
MΩ
V
8
INTEGRATOR
Open-Loop Gain
Dead Zone Current (Hysteresis)
Input Offset Voltage
Input Bias Current
At 10 kHz
57
7
63
dB
100
1
60
nA/LSB
mV
nA
5
150
Output Voltage Range
VS = 10.8 V dc
V
VCO
Maximum Rate
VCO Rate
VS = 12 V dc
Positive Direction
Negative Direction
1.1
8.7
8.7
MHz
kHz/µA
kHz/µA
7.1
7.1
7.9
7.9
VCO Power Supply Sensitivity
Increase
+VS
–VS
+VS
–VS
+0.5
–8.0
–8.0
+2.0
1
%/V
%/V
%/V
%/V
mV
Decrease
Input Offset Voltage
5
Input Bias Current
Input Bias Current Tempco
Input Voltage Range
70
–1.22
380
nA
nA/°C
V
8
Linearity of Absolute Rate
Full Range
Over 0% to 50% of Full Range
Reversion Error
Sensitivity of Reversion Error
to Symmetry of Power Supplies
<2
<1
1.5
% FSD
% FSD
% FSD
%/V of
8
Asymmetry
POWER SUPPLIES
Voltage Levels
+VS
–VS
+VL
Current
IS
+10.8
–10.8
+5
+13.2
–13.2
+13.2
V
V
V
VS @ 12 V
VS @ 13.2 V
+VL @ 5.0 V
؎12
؎19
؎0.5
؎23
؎30
؎1.5
mA
mA
mA
IS
IL
Specification subject to change without notice.
All min and max specifications are guaranteed. Specifications in boldface are tested on all production units at final electrical test.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD2S80A features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. B
–4–