ADG526A/ADG527A
TYPICAL PERFORMANCE CHARACTERISTICS
The multiplexers are guaranteed functional with reduced single or dual supplies down to 4.5 V.
700
600
500
400
300
200
100
0
1.9
1.8
1.7
1.6
1.5
V
V
= 10.8V
= 0V
DD
SS
V
V
= 15V
= 0V
DD
SS
–20
–15
–10
–5
0
5
10
15
20
5
6
7
8
9
10
11
12
13
14
15
V
(V ) (V)
S
SUPPLY VOLTAGE (V)
D
Figure 10. Trigger Levels vs. Power Supply Voltage, Dual or Single Supply,
TA = 25°C
Figure 7. RON as a Function of VD (VS): Single-Supply Voltage, TA = 25°C
700
600
800
700
600
V
V
= +5V
= –5V
DD
SS
500
400
300
200
100
0
500
SINGLE
SUPPLY
400
V
V
= +10.8V
DD
= –10.8V
SS
300
DUAL
SUPPLY
V
V
= +15V
= –15V
DD
SS
200
100
–20
–15
–10
–5
0
5
10
15
20
5
6
7
8
9
10
11
12
13
14
15
V
(V ) (V)
S
D
SUPPLY VOLTAGE (V)
Figure 8. RON as a Function of VD (VS): Dual-Supply Voltage, TA = 25°C
Figure 11. tTRANSITION vs. Supply Voltage: Dual and Single Supplies, TA = 25°C
(Note: For VDD and VSS <10 V; V1 = VDD/VSS, V2 = VSS/VDD; See Figure 20)
100
1.0
0.8
0.6
0.4
0.2
0
V
V
= +16.5V
= –16.5V
DD
SS
10
1
I
I
(ON)
(OFF)
D
D
I
(OFF)
S
0.1
0.01
25
35
45
55
65
75
85
95 105 115 125
5
6
7
8
9
10 11 12 13 14 15 16 17
TEMPERATURE (°C)
SUPPLY VOLTAGE (V)
Figure 12. IDD vs. Supply Voltage: Dual or Single Supply, TA = 25°C
Figure 9. Leakage Current as a Function of Temperature (Leakage Currents
Reduce as the Supply Voltages Reduce)
Rev. C | Page 11 of 20