Applying the AD840  
AD840 SETTLING TIME  
Figures 22 and 24 show the settling performance of the AD840  
in the test circuit shown in Figure 23.  
Figure 24 shows the “long-term” stability of the settling charac-  
teristics of the AD840 output after a 10 V step. There is no evi-  
dence of settling tails after the initial transient recovery time.  
The use of a junction isolated process, together with careful lay-  
out, avoids these problems by minimizing the effects of transis-  
tor isolation capacitance discharge and thermally induced shifts  
in circuit operating points. These problems do not occur even  
under high output current conditions.  
Settling time is defined as:  
The interval of time from the application of an ideal step  
function input until the closed-loop amplifier output has  
entered and remains within a specified error band.  
This definition encompasses the major components which com-  
prise settling time. They include (1) propagation delay through  
the amplifier; (2) slewing time to approach the final output  
value; (3) the time of recovery from the overload associated with  
slewing; and (4) linear settling to within the specified error band.  
Expressed in these terms, the measurement of settling time is  
obviously a challenge and needs to be done accurately to assure  
the user that the amplifier is worth consideration for the  
application.  
Figure 24. AD840 Settling Demonstrating No Settling Tails  
GROUNDING AND BYPASSING  
In designing practical circuits with the AD840, the user must re-  
member that whenever high frequencies are involved, some spe-  
cial precautions are in order. Circuits must be built with short  
interconnect leads. Large ground planes should be used when-  
ever possible to provide a low resistance, low inductance circuit  
path, as well as minimizing the effects of high frequency cou-  
pling. Sockets should be avoided, because the increased  
inter-lead capacitance can degrade bandwidth.  
Figure 22. AD840 0.01% Settling Time  
Feedback resistors should be of low enough value to assure that  
the time constant formed with the circuit capacitances will not  
limit the amplifier performance. Resistor values of less than  
5 kare recommended. If a larger resistor must be used, a small  
(±10 pF) feedback capacitor in connected parallel with the feed-  
back resistor, RF, may be used to compensate for these stray ca-  
pacitances and optimize the dynamic performance of the  
amplifier in the particular application.  
TEK  
TEK  
ERROR  
7A13  
AMP  
(x11)  
7603  
TEK  
OSCILLOSCOPE  
7A18  
HP6263  
4.99k  
499  
DDD5109  
FLAT-TOP  
PULSE  
4.99k  
499  
0.1µF  
50  
+15V  
GENERATOR  
2.2µF  
Power supply leads should be bypassed to ground as close as  
possible to the amplifier pins. A 2.2 µF capacitor in parallel with  
a 0.1 µF ceramic disk capacitor is recommended.  
11  
4
FET PROBE  
TEK P6201  
10  
AD840  
5
6
0.1µF  
499  
CAPACITIVE LOAD DRIVING ABILITY  
499  
2.2µF  
Like all wideband amplifiers, the AD840 is sensitive to capaci-  
tive loading. The AD840 is designed to drive capacitive loads  
of up to 20 pF without degradation of its rated performance.  
Capacitive loads of greater than 20 pF will decrease the dynamic  
performance of the part although instability should not occur  
unless the load exceeds 100 pF. A resistor in series with the out-  
put can be used to decouple larger capacitive loads.  
-15V  
Figure 23. Settling Time Test Circuit  
Figure 23 shows how measurement of the AD840’s 0.01% set-  
tling in 100 ns was accomplished by amplifying the error signal  
from a false summing junction with a very high speed propri-  
etary hybrid error amplifier specially designed to enable testing  
of small settling errors. The device under test was driving a  
420 load. The input to the error amp is clamped in order to  
avoid possible problems associated with the overdrive recovery  
of the oscilloscope input amplifier. The error amp amplifies the  
error from the false summing junction by 11, and it contains a  
gain vernier to fine trim the gain.  
USING A HEAT SINK  
The AD840 draws less quiescent power than most high speed  
amplifiers and is specified for operation without a heat sink.  
However, when driving low impedance loads the current to the  
load can be 4 to 5 times the quiescent current. This will create a  
noticeable temperature rise. Improved performance can be  
achieved by using a small heat sink such as the Aavid Engineer-  
ing #602B.  
REV. C  