ACT8891
Rev 1, 06-Sep-13
SYSTEM CONTROL ELECTRICAL CHARACTERISTICS
(VVP1 = VVP2 = VVP3 = 3.6V, TA = 25°C, unless otherwise specified.)
PARAMETER
Input Voltage Range
TEST CONDITIONS
MIN
2.7
TYP
MAX
5.5
UNIT
V
UVLO Threshold Voltage
UVLO Hysteresis
V
VDDREF Rising
VDDREF Falling
2.2
2.45
200
2.65
V
V
mV
REG1, REG2, REG3, REG4, REG5,
REG6 and REG7 Enabled
Supply Current
420
µA
Shutdown Supply Current
Oscillator Frequency
All Regulators Disabled
1.5
2
3.0
2.2
µA
MHz
V
1.8
1.4
Logic High Input Voltage1
Logic Low Input Voltage
Leakage Current
0.4
1
V
V
nIRQ = VnRSTO = 4.2V
µA
V
Low Level Output Voltage2
ISINK = 5mA
0.35
nRSTO Delay
260ꢂ
160
20
ms
°C
°C
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
Temperature rising
ꢀ: PWRHLD, VSEL are logic inputs.
2: nPBSTAT, nIRQ, nRSTO are open drain outputs.
3: Typical value shown. Actual value may vary from 227.9ms to 291.2ms.
Innovative PowerTM
Active-Semi Proprietary―For Authorized Recipients and Customers
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.
- 13 -
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.