ACT8891  
Rev 1, 06-Sep-13  
REGISTER AND BIT DESCRIPTIONS CONT’D  
OUTPUT ADDRESS BIT  
NAME  
ACCESS  
DESCRIPTION  
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear  
bit to 0 to disable the regulator.  
REG2  
REG2  
0x32  
0x32  
[7]  
[6]  
ON  
R/W  
Regulator Phase Control. Set bit to 1 for regulator to operate  
180° out of phase with the oscillator, clear bit to 0 for regulator  
to operate in phase with the oscillator.  
PHASE  
MODE  
R/W  
R/W  
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM  
under all load conditions, clear bit to 0 to transit to power-  
savings mode under light-load conditions.  
REG2  
0x32  
[5]  
Regulator Turn-On Delay Control. See the REG1, REG2,  
REG3 Turn-on Delay section for more information.  
REG2  
REG2  
0x32  
0x32  
[4:2]  
[1]  
DELAY  
R/W  
R/W  
Regulator Fault Mask Control. Set bit to 1 enable to fault-  
interrupts, clear bit to 0 to disable fault-interrupts.  
nFLTMSK  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
REG2  
REG3  
0x32  
0x40  
[0]  
OK  
-
R
R
[7:6]  
Reserved.  
Primary Output Voltage Selection. Valid when VSEL is driven  
low. See the Output Voltage Programming section for more  
information.  
REG3  
REG3  
REG3  
0x40  
0x41  
0x41  
[5:0]  
[7:6]  
[5:0]  
VSET1  
-
R/W  
R
Reserved.  
Secondary Output Voltage Selection. Valid when VSEL is  
driven high. See the Output Voltage Programming section for  
more information.  
VSET2  
R/W  
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear  
bit to 0 to disable the regulator.  
REG3  
REG3  
0x42  
0x42  
[7]  
[6]  
ON  
R/W  
R/W  
Configures regulator behavior with respect to the nPBIN input.  
Set bit to 0 to enable regulator when nPBIN is asserted.  
PWRSTAT  
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM  
under all load conditions, clear bit to 0 to transition to power-  
savings mode under light-load conditions.  
REG3  
0x42  
[5]  
MODE  
R/W  
Regulator Turn-On Delay Control. See the REG1, REG2,  
REG3 Turn-on Delay section for more information.  
REG3  
REG3  
0x42  
0x42  
[4:2]  
[1]  
DELAY  
R/W  
R/W  
Regulator Fault Mask Control. Set bit to 1 enable to fault-  
interrupts, clear bit to 0 to disable fault-interrupts.  
nFLTMSK  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
REG3  
REG4  
REG4  
0x42  
0x50  
0x50  
[0]  
OK  
-
R
R
[7:6]  
[5:0]  
Reserved.  
Output Voltage Selection. See the Output Voltage  
Programming section for more information.  
VSET  
R/W  
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear  
bit to 0 to disable the regulator.  
REG4  
REG4  
0x51  
0x51  
[7]  
[6]  
ON  
R/W  
R/W  
Output Discharge Control. When activated, discharges LDO  
output to GA through 1.5kwhen in shutdown. Set bit to 1 to  
enable output voltage discharge in shutdown, clear bit to 0 to  
disable this function.  
DIS  
LDO Low-IQ Mode Control. Set bit to 1 for low-power  
operating mode, clear bit to 0 for normal mode.  
REG4  
REG4  
REG4  
REG4  
0x51  
0x51  
0x51  
0x51  
[5]  
[4:2]  
[1]  
LOWIQ  
DELAY  
nFLTMSK  
OK  
R/W  
R/W  
R/W  
R
Regulator Turn-On Delay Control. See the REG4, REG5,  
REG6, REG7 Turn-on Delay section for more information.  
Regulator Fault Mask Control. Set bit to 1 enable to fault-  
interrupts, clear bit to 0 to disable fault-interrupts.  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
[0]  
Innovative PowerTM  
- 11 -  
www.active-semi.com  
Active-Semi ProprietaryFor Authorized Recipients and Customers  
ActivePMUTM is a trademark of Active-Semi.  
I2CTM is a trademark of NXP.  
Copyright © 2013 Active-Semi, Inc.