 浏览型号ACT81460VM101-T的Datasheet PDF文件第6页浏览型号ACT81460VM101-T的Datasheet PDF文件第7页浏览型号ACT81460VM101-T的Datasheet PDF文件第8页浏览型号ACT81460VM101-T的Datasheet PDF文件第9页浏览型号ACT81460VM101-T的Datasheet PDF文件第11页浏览型号ACT81460VM101-T的Datasheet PDF文件第12页浏览型号ACT81460VM101-T的Datasheet PDF文件第13页浏览型号ACT81460VM101-T的Datasheet PDF文件第14页  
ACT81460  
Rev 1.0, 18-Dec-2018  
VSYS OV Deglitch Time  
Operating Supply Current  
160  
200  
240  
µs  
All regulators enabled but no load, boost regulator  
is disabled. Charger off, power supplied from  
VSYS.  
6
8
µA  
LDO1 enabled but no load. BUCK1/2, Buck-boost,  
Boost, and Charger disabled. Battery FET enabled  
and supplied from VBAT. References and moni-  
tors enabled.  
Operating Supply Current  
Operating Supply Current  
2.1  
2.7  
2.6  
3.2  
µA  
µA  
LDO1 and one BUCK regulator enabled with no  
load. Charger disabled. Power supplied from  
VSYS. References and monitors enabled.  
Thermal Low Power Threshold  
Thermal Warning Temperature  
Thermal Shutdown Temperature  
Thermal Shutdown Hysteresis  
70  
125  
155  
25  
°C  
°C  
°C  
°C  
Temperature rising.  
Temperature rising.  
115  
140  
135  
170  
Time from VSYS > UVLO threshold to Internal  
Power-On Clear (POR)  
Power Up Delay after initial VSYS  
Startup Delay after initial VSYS  
5
ms  
ms  
Time from VSYS > UVLO threshold to start of first  
regulator turning On.  
10  
Time from I2C command to clear sleep mode to  
time when the first regulator turns ON with mini-  
mum turn on delay configuration.  
Transition time from Sleep State  
(SLEEP) to Active State  
90  
56  
µs  
µs  
Time from turn off event to when the first power  
rail turns off with minimum turn off delay configura-  
tion.  
Turn Off Delay  
Regulator Startup Delay Program-  
mable Range between turn on  
events.  
ONDLY=000  
ONDLY=001  
ONDLY=010  
ONDLY=011  
ONDLY=100  
ONDLY=101  
ONDLY=110  
ONDLY=111  
0
0.5  
1
2
5
10  
15  
20  
ms  
Regulator Turn Off Delay Program-  
mable Range  
Configurable in 4ms steps  
0
60  
ms  
ms  
nRESET, Delay Timing  
20  
100  
Configurable to 20, 40, 60 or 100ms.  
Innovative PowerTM  
ActiveSwitcherTM is a trademark of Active-Semi  
www.active-semi.com  
Copyright © 2018 Active-Semi, Inc.  
10