ACT5830
Rev 2, 20-Jan-11
SYSTEM MANAGEMENT
ELECTRICAL CHARACTERISTICS
(VBAT = VIN1 = VIN2 = 3.6V, TA = 25°C, unless otherwise specified.)
PARAMETER
BAT Operating Voltage Range
BAT UVLO Threshold
TEST CONDITIONS
MIN
2.6
TYP MAX UNIT
5.5
2.5
V
V
BAT Voltage Rising
BAT Voltage Falling
BAT Rising
2.2
2.35
80
0.1
5
BAT UVLO Hysteresis
mV
BAT UVLO Delay
nRST Delay
ms
BAT Falling
65
ms
REG, LDO1, LDO2 and LDO3 Enabled with
No Load and CHGR Disabled
0.26
0.5
mA
No Load BAT Supply Current
REG, All LDOs Enabled and CHGR Disabled.
0.45
1.25
75
0.75
1.26
mA
V
REF Output Voltage
1.24
1.4
Reference PSRR
C
REF = 0.01µF, f = 1kHz
100mA Sink Current
ODx = VBAT
dB
ꢀ
ODx Output On Resistance
ODx Output Leakage Current
Logic High Input Voltage
Logic Low Input Voltage
Logic Low Output Voltage
Logic Leakage Current
4
V
10
µA
V
0.4
0.3
1
V
nON, nRST, ISINK = 5mA
nON = VnRST = VCHG_IN = 4.2V
V
V
µA
°C
°C
Thermal Shutdown Temperature Temperature rising
160
20
Thermal Shutdown Hysteresis
Temperature falling
Innovative PowerTM
- 8 -
www.active-semi.com
Copyright © 2010 Active-Semi, Inc.
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.