ACT2803  
Rev 1, May-12-2016  
APPLICATIONS INFORMATION  
In charge mode, the battery charger provides bias  
current to balance battery charge. The balance  
resistor is either connected to upper battery or  
lower battery depending on which battery voltage is  
higher. The balance resistor is connected in parallel  
with one battery that is higher than the other  
battery. For extremely unbalanced 2S batteries, the  
charger takes a few cycles to make two battery  
voltage balanced. For some applications, like  
removable dual cell batteries, a charger is required  
to balance dual cells in one charge cycle. In this  
case, the circuit shown in Figure 5 is recommended.  
The balance current through the 22 Ohm  
resistor needs to be higher than EOC current  
threshold.  
the LEDs are 0.5Hz with 1s on and 1s off.  
In HZ mode, when PB is pressed for 40ms, Buck  
turns on. If VBAT<LED1, LED1 starts flashing until  
Buck turns off.  
Conventional indication patterns could behave to  
have two application. Setting RPT=4kΩ to have  
“Always On”, setting RPT=12kΩ to have “5s  
Indication”. The behaviors for both setting are same  
in charge mode.  
See below table for more information.  
INDICATION PATTERN  
RPT  
#
Conventional  
1a  
4kΩ  
Always On In Discharge  
Conventional  
1b  
2
12kΩ  
24kΩ  
40kΩ  
56kΩ  
5s Indication in Discharge  
Breathing  
5s Indication in Discharge  
Bottom Charging  
3
5s Indication in Discharge  
Circulating  
4
5s Indication in Discharge  
Below shows 4 LED indication patterns.  
Figure 5: Cell balance  
LED Indication  
ACT2803 is designed 5 levels of PT pin voltage into  
5 application patterns. A resistor is connected from  
PT pin to ground and the voltage at PT pin  
programs the LED indication patterns shown in  
Figure 6 .  
LED1-4 Refreshing ycle  
Every time when VIN is plugged in or a PB is  
pushed, LED1, 2, 3, 4 turns on sequentially at 0.5s  
interval, like a LED scanning, and then goes into  
corresponding mode defined by PT pin.  
LED1-4 Fault Alarm Signal  
At fault conditions, actions are taken. In the  
meantime, all the 4 LEDs turn on/off with 0.5s on  
and 0.5s off for 10 seconds to send alarm signal  
out. The fault conditions include battery OVP, UVP,  
OTP.  
PCB Board Layout Guidance  
When laying out the printed circuit board, the  
following checklist should be used to ensure proper  
operation of the IC.  
1. Arrange the power components to reduce the  
AC loop area.  
Figure 6: LED Indication  
In discharge mode, when battery voltage goes  
below LED1 threshold, LED1 starts flashing until  
Buck (discharge mode) turns off due to either light  
load or Buck UVLO. The flash frequencies for all  
Innovative PowerTM  
- 15 -  
www.active-semi.com  
Copyright © 2016 Active-Semi, Inc.  