 浏览型号ACE24C1024DP+UH的Datasheet PDF文件第1页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第2页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第3页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第4页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第6页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第7页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第8页浏览型号ACE24C1024DP+UH的Datasheet PDF文件第9页  
ACE24C1024  
Two-wire Serial EEPROM  
AC Characteristics  
Applicable over recommended operating range from: TA = -40to +85, VCC = +1.7V to +5.5V, CL = 100 pF (unless otherwise  
noted). Test conditions are listed in Note2.  
1.7-volt  
2.5-volt 5.5-volt  
Symbol  
Parameter  
Units  
Min Max Min Max Min Max  
fSCL  
TLOW  
THIGH  
Ti1  
Clock Frequency, SCL  
Clock Pulse Width Low  
Clock Pulse Width High  
Noise Suppression Time  
Clock Low to Data Out Valid  
Time the bus must be free before a new  
transmission can Start  
Start Hold Time  
400  
100  
1000  
1000 kHz  
1300  
600  
400  
400  
400  
400  
ns  
ns  
50  
50  
TAA  
20 900 20 550 20 550  
ns  
1
TBUF  
1300  
500  
500  
ns  
THD.STA  
TSU.STA  
THD.DAT  
TSU.DAT  
TR  
600  
600  
0
250  
250  
0
250  
250  
0
ns  
ns  
Start Setup Time  
Data In Hold Time  
ns  
Data In Setup Time  
100  
100  
100  
ns  
Inputs Rise Time  
300  
300  
300  
100  
300  
100  
ns  
TF  
Inputs Fall Time  
ns  
TSU.STO  
TDH  
Stop Setup Time  
600  
50  
250  
50  
250  
50  
ns  
Data Out Hold Time  
Write Cycle Time  
ns  
TWR  
5
5
5
ms  
Write  
Cycles  
Endurance1  
3.3V, 25, Page Mode  
1,000,000  
Notes:1. This parameter is characterized and not 100% tested.  
2.AC measurement conditions:  
RL (connects to Vcc): 1.3KΩ  
Input pulse voltages: 0.3 Vcc to 0.7 Vcc  
Input rise and fall times: 50 ns  
Input and output timing reference voltages: 0.5Vcc  
Device Operation  
Clock and Data Transitions:  
The SDA pin is normally pulled high with an external device. Data on the SDA pin may change only  
during SCL low time periods (refer to Figure 4). Data changes during SCL high periods will indicate a  
start or stop condition as defined below.  
Start Condition:  
A high-to-low transition of SDA with SCL high is a start condition which must precede any other  
command (refer to Figure 5).  
VER 1.4  