3.3.11. Flicker : Cb  
1) Set 5.5 lx illumination condition with blue filter, then measure the signal output.  
2) Make blue chroma signal B – Y.  
3) Measure odd field output value ( CB.ODD ).  
4) Measure even field output value ( CB.EVE ).  
5) Detect Flicker Cb with the following formula.  
FlkCb [ % ] = ABS ( 2 x ( CB.ODD – CB.EVE ) / ( CB.ODD + CB.EVE ) ) x 100  
3.3.12. Line crawl : R  
1) Set 5.5 lx illumination condition with red filter, then measure the signal output.  
2) Make composition of luminance signal Y.  
3) Apply low pass filter to Y ( ex : rank filter ).  
3) Calculate difference between Y signal lines for the same field.  
4) Select maximum difference ( LCLEV ) value.  
5) Detect Line crawl R with the following formula.  
LcR [ % ] = ABS ( LCLEV / Y.mean ) x 100  
3.3.13. Line crawl : B  
1) Set 5.5 lx illumination condition with blue filter, then measure the signal output.  
2) Make composition of luminance signal Y.  
3) Apply low pass filter to Y ( ex : rank filter ).  
4) Calculate difference between Y signal line for the same field.  
5) Select maximum difference ( LCLEV ) value.  
6) Detect Line crawl B with the following formula.  
LcB [ % ] = ABS ( LCLEV / Y.mean ) x 100  
3.3.14. Line crawl : G  
1) Set 5.5 lx illumination condition with green filter, then measure the signal output.  
2) Make composition of luminance signal Y.  
3) Apply low pass filter to Y ( ex : rank filter ).  
4) Calculate difference between Y signal lines for the same field.  
5) Select maximum difference ( LCLEV ) value.  
6) Detect Line crawl G with the following formula.  
LcG [ % ] = ABS ( LCLEV / Y.mean ) x 100  
3.3.15. Line crawl : W  
1) Set 1.0 lx illumination condition  
2) Make composition of luminance signal Y.  
3) Apply low pass filter to Y ( ex : rank filter ).  
4) Calculate difference between Y signal line for the same field.  
5) Select maximum difference ( LCLEV ) value.  
6) Detect Line crawl W with the following formula.  
LcW [ % ] = ABS ( LCLEV / Y.mean ) x 100  