8. ELECRICAL CHARACTERISTICS  
8.1 Absolute Maximum Ratings  
PARAMETER  
Storage Temperature Plastic Packages  
Ambient Temperature with Power Applied  
Voltage with Respect to Ground VDD (Note 1)  
A9, #OE, and #RESET (Note 2)  
#WP/ACC  
All other pins (Note 1)  
Output Short Circuit Current (Note 3)  
Notes:  
RATING  
-65 to +150  
-65 to +125  
-0.5 to +4.0  
-0.5 to +12.5  
-0.5 to +10.5  
-0.5 to VDD +0.5  
200  
UNIT  
°C  
°C  
V
V
V
V
mA  
1. Minimum DC voltage on input or I/O pins is -0.5 V. During voltage transitions, input or I/O pins may overshoot VSS to  
-2.0 V for periods of up to 20 nS. Maximum DC voltage on input or I/O pins is VDD +0.5 V. During voltage transitions,  
input or I/O pins may overshoot to VDD +2.0 V for periods up to 20 nS.  
2. Minimum DC input voltage on pins A9, #OE, #RESET, and #WP/ACC is -0.5 V. During voltage transitions, A9, #OE,  
#WP/ACC, and #RESET may overshoot VSS to -2.0 V for periods of up to 20 nS. Maximum DC input voltage on pin A9  
is +12.5 V which may overshoot to +14.0 V for periods up to 20 nS. Maximum DC input voltage on #WP/ACC is +9.5 V  
which may overshoot to +12.0 V for periods up to 20 nS.  
3. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than  
one second.  
Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device.  
This is a stress rating only; functional operation of the device at these or any other conditions above those  
indicated in the operational sections of this data sheet is not implied. Exposure of the device to absolute maximum  
rating conditions for extended periods may affect device reliability.  
8.2 Operating Ranges  
PARAMETER  
RATING  
-40 to +85  
0 to +70  
-20 to +85  
2.7 to 3.6  
3.0 to 3.6  
UNIT  
Industrial  
Commercial  
Extend  
W19B320S  
W19L320S  
Ambient Temperature (TA)  
°C  
VDD Supply Voltages  
V
Operating ranges define those limits between which the functionality of the device is guaranteed.  