欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BD1E13A2C06 参数 Datasheet PDF下载

BCM4414BD1E13A2C06图片预览
型号: BCM4414BD1E13A2C06
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 42 页 / 1364 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第32页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第33页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第34页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第35页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第37页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第38页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第39页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第40页  
BCM4414xD1E13A2yzz  
READ_K_FACTOR Command (D1h)  
DISABLE_FAULT Command (D7h)  
If PAGE data byte is equal to (01h - 04h), command will return a  
reported individual BCM’s K factor in the following format:  
DISABLE_FAULT  
MSB  
LSB  
K_FACTORACTUAL = K_FACTORREPORTED 2-16(V/V)  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
IOUT_OC_FAULT  
Reserved  
The K factor is defined in a BCM to represent the ratio of the  
transformer winding and hence is equal to VLO / VHI.  
VIN_OV_FAULT  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
VIN_UV_FAULT  
Reserved  
READ_BCM_ROUT Command (D4h)  
If PAGE data byte is equal to (01h - 04h), command will return  
a reported individual BCM’s LO side resistance in the following  
format:  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
0
1
0
0
0
0
0
0
0
0
1
0
1
0
0
0
b
BCM_RLO_ACTUAL = BCM_RLO_REPORTED • 10-5(Ω)  
Unsupported bits are indicated above. A one indicates that the  
supervisory fault associated with the asserted bit is disabled.  
SET_ALL_THRESHOLDS Command (D5h)  
The values of this register block are set in non-volatile memory and  
can only be written when the BCMs are disabled.  
This command allows the host to disable the supervisory faults  
and respective statuses. It does not disable the powertrain analog  
protections or warnings with respect to the set limits in the SET_  
ALL_THRESHOLDS Command.  
SET_ALL_THRESHOLDS_BLOCK (6 Bytes)  
IOUT_OC_WARN_ LIMIT  
IOUT_OC_FAULT_ LIMIT  
The HI side undervoltage can only be disabled to a pre-set low limit  
as shown in the functional reporting range in the BCM data sheet.  
VIN_OV_WARN_ LIMIT  
VIN_OV_FAULT_ LIMIT  
OT_WARN_LIMIT  
OT_FAULT_LIMIT  
5
4
3
2
1
0
h
64 64 64 64 64 64  
The values of this register block are set in non-volatile memory and  
can only be written when the BCMs are disabled.  
This command provides a convenient way to configure all of the  
limits, or any combination of limits described previously using one  
command.  
VHI overvoltage, overcurrent and overtemperature values are all set  
to 100% of the specified supervisory limits by default and can only  
be set to a lower percentage.  
To leave a particular threshold unchanged, set the corresponding  
threshold data byte to a value greater than (64h).  
BCM® in a VIA Package  
Page 36 of 42  
Rev 1.5  
10/2016  
vicorpower.com  
800 927.9474  
 复制成功!