BCM4414xD1E13A2yzz
READ_VIN Command (88h)
READ_POUT Command (96h)
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s HI side voltage in the following format:
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s LO side power in the following format:
VHI_ACTUAL = VHI_REPORTED • 10-1(V)
PLO_ACTUAL = PLO_REPORTED (W)
READ_IIN Command (89h)
If PAGE data byte is equal to (00h), command will return the sum of
active BCM’s LO side power.
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s HI side current in the following format:
MFR_VIN_MIN Command (A0h),
MFR_VIN_MAX Command (A1h),
MFR_VOUT_MIN Command (A4h),
MFR_VOUT_MAX Command (A5h),
MFR_IOUT_MAX Command (A6h),
MFR_POUT_MAX Command (A7h)
IHI_ACTUAL = IHI_REPORTED • 10-3(A)
If PAGE data byte is equal (00h), command will return the sum of
active BCM’s HI side current.
READ_VOUT Command (8Bh)
These values are set by the factory and indicate the device HI side/
LO side voltage and LO side current range and LO side power
capacity.
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s LO side voltage in the following format:
The internal controller will report the rated BCM HI side voltage
minimum and maximum in Volts, LO side voltage minimum and
maximum in Volts, LO side current maximum in Amperes and LO
side power maximum in Watts.
VLO_ACTUAL = VLO_REPORTED • 10-1(V)
READ_IOUT Command (8Ch)
If PAGE data byte is equal to (00h) then:
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s LO side current in the following format:
n MFR_VIN_MIN COMMAND (A0h) will return the highest
MFR_VIN_MIN of all active BCMs
n MFR_VIN_MAX COMMAND (A1h) will return the lowest
MFR_VIN_MAX of all active BCMs
ILO_ACTUAL = ILO_REPORTED • 10-2(A)
n MFR_VOUT_MIN COMMAND (A4h) will return the highest
If PAGE data byte is equal (00h), command will return the sum of
active BCM’s LO side current.
MFR_VOUT_MIN of all active BCMs
n MFR_VOUT_MAX COMMAND (A5h) will return the lowest
MFR_VOUT_MAX of all active BCMs
READ_TEMPERATURE_1 Command (8Dh)
n MFR_IOUT_MAX COMMAND (A6h) will return the SUM of
MFR_IOUT_MAX of all active BCMs
If PAGE data byte is equal to (01h - 04h), command will return a
reported individual BCM’s temperature in the following format:
n MFR_POUT_MAX COMMAND (A7h) will return the SUM of
MFR_POUT_MAX of all active BCMs
TACTUAL = TREPORTED (°C)
If PAGE data byte is equal (00h), command will return the
maximum temperature of active BCM’s.
BCM® in a VIA Package
Page 35 of 42
Rev 1.5
10/2016
vicorpower.com
800 927.9474